Technical Description - Waeco Refresh-o-mat HD Operating Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Refresh-o-mat HD
6

Technical description

6.1
General description
The ultrasonic cells diffuse the air-conditioning cleaning agent into a fine
spray. The spray is directed through the hose by a fan to the suction open-
ings of the air-conditioning system.
The Refresh-o-mat switches off automatically in the following events:
 The fluid reaches the minimum level
 The tank is overfilled (the Refresh-o-mat does not start if the tank is too
full)
 A temperature of 65 °C is exceeded
6.2
Control panel
Item in
fig. 3,
Description
page 3
1
HIGH
TEMPERATURE
2
READY/ON
3
HIGH LEVEL
4
START/STOP
EN
Explanation/function
Red LED
Lights up if the interior temperature exceeds
65 °C. The device stops automatically.
Green LED
 Flashes while the tank is being filled up
 Lights up while it is being cleaned
Green LED
Lights up if the tank is overfilled with fluid. The
device stops automatically.
Switches the device on or off.