Download Print this page

Whirlpool LTG5243DT5 Installation Instructions Manual page 5

24" (61cm) gas washer/dryer

Advertisement

EmectricaI Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground
prong.
Do not use an adapter,
Do not use an extension
cord.
Faimure to follow these }nstruct}ons
can resumt }n death,
fire, or emectr}ca{ shock.
A 120-volt, 60-Hz., AC-only, 15- or 20-amp, fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended.
It is also recommended that a separate circuit
serving only this appliance be provided.
To minimize possible shock hazard, the cord must be plugged
into a mating, 3 prong, grounding-type
outlet, grounded in
accordance with local codes and ordinances.
If a mating
outlet is not available, it is the personal responsibility
and
obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
IMPORTANT: The washer/dryer
must be electrically grounded
in accordance with local codes, or in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70.
If codes permit and a separate ground wire is used, it is
recommended
that a qualified electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure the
washer/dryer is properly grounded.
Do not have a fuse in the neutral or ground circuit.
GROUNDING
INSTRUCTIONS
[]
For a grounded, cord-connected
washer/dryer:
This washer/dryer
must be grounded. In the event of
malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of least resistance for
electric current. This washer/dryer
is equipped with a cord
having an equipment-grounding
conductor and a grounding
plug. The piug must be plugged into an appropriate outlet
that is properly installed and grounded in accordance with
all local codes and ordinances.
WARNING:
improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or
personnel if you are in doubt as to whether the washer/dryer
is properly grounded. Do not modify the plug provided with
the washer/dryer:
if it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
SAVE THESE
INSTRUCTIONS
Explosion
Hazard
Use a new AGA or CSA approved
gas supply
mine.
Install a shut-off
valve.
Securemy tighten
aH gas connections.
ff connected
to LP, have a qualified
person make sure
gas pressure
does not exceed 13" (33 cm) water
comumn.
Exampmes of a quamified person
include:
licensed
heating
personnem,
authorized
gas company
personnel,
and
authorized
service
personnel
Failure to do so can resuJt in death, explosion,
or fire.
Gas Type
Natural Gas:
This washer/dryer
is equipped for use with Natural gas. It is
design-certified
by CSA International for LP (propane or butane)
gases with appropriate conversion.
Your washer/dryer must have the correct burner for the type of
gas in your home. Burner information is located on the rating
plate in the door well of your dryer. If this information does not
agree with the type of gas available, contact your dealer or call
the phone numbers referenced on the front page of your
"Washer/Dryer
User Instructions."
LP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier.
IMPORTANT: The gas installation must conform with local codes,
or in the absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54.
Gas Supply
Line
1/2"IPS pipe is recommended.
3/8"approved tubing is acceptable for lengths under
20 ft (6.1 m) if local codes and gas supplier permit.
Lengths over 20 ft (6.1 m) should use larger tubing.
Must include 1/3"NPT minimum plugged tapping accessible
for test gauge connection,
immediately upstream of the gas
supply connection to the dryer (see illustration).
Gas supply line coupling must be 34" (86.4 cm) to 37" (94 cm)
from the floor.

Advertisement

loading

This manual is also suitable for:

Ltg5243dq5