ACD CHD09KCH19S Owner's Manual

ACD CHD09KCH19S Owner's Manual

Ductless single zone heat pump

Advertisement

Quick Links

Owner's Manual
DUCTLESS SINGLE ZONE
HEAT PUMP
Models:
CHD09KCH19S
CHD12KCH17S
CHD18KCH17S
CHD24KCH18S
Please read this owner's manual carefully
before operating the unit and keep it for future reference.

Advertisement

Table of Contents
loading

Summary of Contents for ACD CHD09KCH19S

  • Page 1 Owner’s Manual DUCTLESS SINGLE ZONE HEAT PUMP Models: CHD09KCH19S CHD12KCH17S CHD18KCH17S CHD24KCH18S Please read this owner’s manual carefully before operating the unit and keep it for future reference.
  • Page 2: Table Of Contents

    CONTENTS Safety precautions ..................Parts name ....................Operation and introduction of remote contr oller ..........Clean and maintenance ................Checked items before maintenance ............. Installation notice ..................Installation of indoor unit ................Test and operation ..................Configuration of connection pipe ..............
  • Page 3 Explanation of Symbols WARNING This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to CAUTION property. Indicates important but not hazard-related information, used NOTICE to indicate risk of property damage. Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons.
  • Page 4 FCC WARNING WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 5 IC STATEMENT This equipment complies with FCC’s and IC’s RF radiation exposure limits set forth for an uncontrolled environment. The antenna(s) used for this transmitter must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.
  • Page 6: Safety Precautions

    Safety precautions WARNING Installation Installation or maintenance The grounding resistance must be performed by should comply with nation- qualified professionals. al electric safety regula- The appl iance shal l be tions. i nstalled in accordance with Air Conditioner should be national wiring regulations.
  • Page 7 Safety precautions CAUTION Installation Instructions for installation For the air conditioner with- and use of this product are out plug, a circuit breaker provided by the manufac- must be installed in the turer. line. Select a location which is The yellow-green wire in out of reach for children A/C is the ground wire, and far away from animals...
  • Page 8 Safety precautions WARNING Operation and Maintenance tioner to multi-purpose soc- This appliance can be used ket. Otherwise, it may cau- by children aged from 8 se fire hazard. years and above and per- Do disconnect power supp- sons with reduced physi- ly when cleaning air condi- tioner.
  • Page 9 Safety precautions CAUTION Operation and Maintenance frequently. Do not spill water on the re- Air conditioner gives off mote controller, otherwise burning smell. the remote controller may Indoor unit is leaking. be broken. Do not use fire or hair dry- er to dry the filter to avoid deformation or fire hazard.
  • Page 10: Parts Name

    Parts name Indoor Unit air inlet panel filter aux. button air outlet horizontal louver If remote controller is lost or damaged, please use aux. button to turn on or turn off the air conditioner. The operation in details is as below: As shown in the figure, open panel and press aux.
  • Page 11: Operation And Introduction Of Remote Controller

    Operation and introduction of remote controller Introduction for icons on display Buttons on remote controller screen I feel Set fan speed Turbo mode Send signal Auto mode Cool mode Dry mode Fan mode Heat mode Sleep mode 8℃ heating function Power limiting operation Health mode ON/OFF...
  • Page 12 Introduction for buttons on adjust fan blowing angle. remote controller When selecting heating mode, the air condition- er operates under heat mode. Press " " or " " NOTE button to adjust set temperature. Press "FAN" ● This is a general use remote controller. It could be button to adjust fan speed.
  • Page 13 turn to quick COOL or quick HEAT mode. " " ically swing up & down at maximum angle. icon is displayed on remote control. Press this ● When selecting " ", air condition- 、 、 、 、 button again to exit turbo function and " "...
  • Page 14 Sleep, circulate between these, after electrified, NOTE Sleep Cancel is defaulted. ● Under on and off status, you can set T-OFF or T-ON Sleep 1 is Sleep mode 1, in Cool modes; sleep ● simultaneously. ● status after run for one hour, the main unit setting Before setting T-ON or T-OFF, please adjust the clock time.
  • Page 15 Function introduction for WiFi combination buttons Press " WiFi " b utton to turn on WiFi function, " WiFi " icon will be displayed on the remote control; Energy-saving function Hold " WiFi " button for 5s to turn off WiFi function and "...
  • Page 16 When the remote control is turned off, power ● Child lock function limiting function is cancelled. If you want to acti- vate the function, please repress this button. Press " " and " " simultaneously to turn on or If the current power is lower than the maximum ●...
  • Page 17: Clean And Maintenance

    Clean and maintenance WARNING ■ The filter should be cleaned every three months . If there is much dust in the operation environme- WARNING nt, clean frequency can be increased. ■ Turn off the air conditioner and disconnect the ■ After removing the filter, do not touch fins to power before cleaning the air conditioner to av- avoid injury.
  • Page 18: Checked Items Before Maintenance

    Checked items before maintenance General phenomenon analysis Phenomenon Solution Check items Please check below items before asking for maintenance. If the malfunction still can’t be Whether there’s od- Eliminate the odour Odours are our source, such as eliminated, please contact local dealer or qualified source.
  • Page 19: Installation Notice

    Installation notice WARNING sure that the unit is running in cooling mode. Then, fully close the valve at high pressure side (liquid valve). About 30-40 seconds later, fully close the valve at low pressure side (gas valve), immediately stop the unit and disconnect power.
  • Page 20 Selection of installation location Requirements for electric connection Basic requirement 7.If the supply cord is damaged, it must be repla- Installing the unit in the following places may cau- ced by the manufacturer, its service agent or se malfunction. If it is unavoidable, please consu- similarly qualified persons in order to avoid a lt the local dealer: hazard .
  • Page 21: Installation Of Indoor Unit

    Installation of indoor unit NOTE Indoor outdoor ● Pay attention to dust prevention Step 1: sures when opening the hole. Choose installation location Φ55 5-10 Φ70 Recommend the installation location to the client and then confirm it with the client. Step 2: Step 4: Install wall-mounting frame...
  • Page 22 Tightening torque (N . m) drain hose Hex nut diameter 1/4'' 15~20 3/8'' 30~40 1/2'' 45~55 insulating pipe 5/8'' 60~65 NOTE 3/4'' 70~75 ● Add insulating pipe in the indoor drain hose in order to prevent condensation. ● The plastic expansion particles are not provided. Wrap the indoor pipe and joint of connection pipe with insulating pipe, and then wrap it Step 7:...
  • Page 23 drain hose connection pipe 3. Remove the wire clip; connect the power conn- band ection wire to the wiring terminal according to the color; tighten the screw and then fix the po- wer connection wire with wire clip. indoor power cord Bind them evenly.
  • Page 24: Test And Operation

    Test and operation Check after installation ● Check according to the following requirement after finishing installation. Items to be checked Possible malfunction Has the unit been The unit may drop, shake or installed firmly? emit noise. It may cause insufficient Have you done the refri- cooling(heating) capacity.
  • Page 25: Configuration Of Connection Pipe

    Configuration of connection pipe Additional refrigerant charging amount for R22, R407C, R410A and R134a Standard length of connection pipe: 5m, 7.5m, Min. length of connection pipe is 3m. Max. length of connection pipe is shown as below. Max. length of connection pipe Max.
  • Page 26 B: Remove the burrs smooth surface Remove the burrs with shaper and prevent the ● burrs from getting into the pipe. improper expanding pipe shaper leaning damaged crack uneven surface thickness downwards the length is equal Working temperature range Indoor side Outdoor side C: Put on suitable insulating pipe DB/WB (°C /°F)