Mitsubishi Electric TPKA0A 1KA Series Installation Manual page 13

Split-system heat pump
Hide thumbs Also See for TPKA0A 1KA Series:
Table of Contents

Advertisement

Available languages

Available languages

6. Electrical work
1
C
B
A
2
D
Fig. 6-8
7
A
Fig. 6-10
A
Fig. 6-11
A
Fig. 6-9
1
4
2
3
6
5
8
B
Fig. 6-12
6.2. Remote controller
6.2.1. For wired remote controller
1) Two remote controllers setting
If two remote controllers are connected, set one to "Main" and the other to
"Sub".
For setting procedures, refer to "Function selection of remote controller" in the
operation manual for the indoor unit.
6.2.2. For wireless remote controller
1) Installation area
• Area in which the remote controller is not exposed to direct sunshine.
• Area in which there is no nearby heating source.
• Area in which the remote controller is not exposed to cold (or hot) winds.
• Area in which the remote controller can be operated easily.
B
• Area in which the remote controller is beyond the reach of children.
2) Installation method (Fig. 6-8)
1 Attach the remote controller holder to the desired location using 2 tapping
screws.
2 Place the lower end of the controller into the holder.
A Remote controller B Wall C Display panel D Receiver
• The signal can travel up to approximately 7 meters (in a straight line) within
45 degrees to both right and left of the center line of the receiver.
3) Setting (Clock setting) (Fig. 6-9)
1 Insert batteries or press the
[CLOCK] A and [:] B blinks.
2 Press the
button with something sharp.
3 Press the
button to set the time.
Press the
button to set the Day.
4 Press the
button with something sharp at the end.
[CLOCK] and [:] lighted.
4) Mode display setting (to cooling only setting)
(The factory setting is "COOL/DRYING/AUTO/FAN/HEAT")
1. Press the
2. Press the
button 3 in 5 seconds. Model setting screen will be
displayed.
3. Press the
button 7. Operation mode A blinks. (Fig. 6-10)
4. Press the
button 4 to change setting No.
5. Check that setting No. "6" is displayed and only
mode A, then press the
5) Initial setting
The following settings can be made in the initial setting mode.
Item
Temperature unit
ºC/ºF
Time display
12-hour format/24-hour format
Pair No.
0–3
Backlight
On/Off
5-1. Switching to the initial setting mode
1. Press the
2. Press the
button 2.
The Function setting screen will be displayed and the function No. A will
blink. (Fig. 6-11)
Press the
button 4 to change the function No.
3. Check that function No. "1" is displayed, and the
3.
The display setting screen will be displayed. (Fig. 6-12)
A
C
D
button with something sharp.
button 1 to stop the air conditioner.
blink at operation
button 3 in 5 seconds.
Setting
Fig. 6-12
A
B
C
D
button 1 to stop the air conditioner.
press the button
12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents