Follow caution information wherever you see this symbol. 1 Spcifications Model V18C01A Power Source AC 220~240V,50/60Hz Motor Power MAX. 800W ≥170W Air Power Dust Capacity 2.0L Cord Length Weigth(Main Body) 4.5Kg Dimension(W*L*H) 410*265*240mm Attachments Multi surface floor nozzle, combination tool, hose,...
4 Repair of Main Parts 4.1 Upper、Lower Body、Motor cover、Re-winder、 Hose Assembly Press the button of hose connector to release hose from main body. Remove the 6 screws from the body. Remove the four screws one by one from Then take the middle cover away. the motor cover and PCB.
Remove the two screws from the motor Pull the entire plug out smoothly and cover. Then take the motor cover away. press the rewinder frame to take all the cord in to test whether it works well. 4.2 Motor Removing Step 1 Detach the body partition and cord reel ass.
Step 1 Disconnect the hose by depressing the projection in the hole on each side of handle. Assembling Step 1 Slide the projection on the hose supporter of the hose into on either side. 5 Trouble Shooting Chart Trouble Possible Causes Countermeasure 1.The plug is not plugged in...
Full dust indicator of The buoy stuck channel adverse action Spring is broken Repair full dust indicator Repair full dust indicator 6 Replacement Parts List Part Name Part Code Specs. AIRINLET HEPA 12175000077043 CORD REWIND 12175000077041 According to the power cord 1 ASSEMBLY 3…...
Need help?
Do you have a question about the V18C01A and is the answer not in the manual?
Questions and answers