ZX225USLC-5 Excavator
1.
Visually inspect the BreatheSafe system for any damage.
2.
Visually inspect the cabin for any damage to doors, windows, seals.
3.
Please remove dust & debris from shoes and clothes before entering the cabin.
4.
Ensure door(s) and windows are closed correctly.
5.
Start engine and turn HVAC on to speed 2 (medium speed).
After fixed speed delay, the BreatheSafe display will show 50 Pascals or pre-set value.
6.
Cab Air Conditioning
BreatheSafe recommends OEM air conditioning fan is set at mid speed or greater to circulate air around the breathing zone and
minimise CO₂.
Acceptable operating range for BreatheSafe fan 10-80%. >80% recommend maintenance.
Fixed Fan Start Delay
Allows the operator to carry out pre-start checks – limiting at 30% fan speed, press the red text to disable.
CO₂ Level Alert (if equipped)
Ensure air conditioning fan is set at mid speed or greater to circulate air and minimise CO₂.
Low Pressure Alarm
Cabin is not maintaining positive pressure – check doors and windows are closed correctly.
Refer to maintenance department to check filters and cabin sealing. Ensure filters are serviceable.
Check Filter
Reminder to inspect or replace filter. Service hour meter requires re-set.
Refer to maintenance department.
OPERATORS CHECKLIST
The system is working correctly when the pascal value is green.
>> There is no further action required <<
NORMAL OPERATING CONDITION
ALERTS
PRE-START