BLA-545/A-545/BLA-530/A-530
2. Set
the
distortion
analyzer
controls
for
voltge
measurements
and
apply
power
to
the
amplifier.
Set
the
volume
control
fully
CCW.
Set
the
SELECTOR
switch
to
PHONO.
MIXING
volume
control fully CCW (SOURCE).
. If the distortion analyzer indicates more than 1.0 mV
refer to the trouble analysis section of this manual.
. Set the volume
control
fully CW.
If the distortion
analyzer
indicates
more
than
20 mV,
refer to the
trouble analysis section of this manual.
MAXIMUM POWER OUTPUT
. Connect
the audio oscillator to the AUX
input. Set
audio oscillator frequency to 1 kHz. Set SELECTOR
switch to AUX.
. With
the
distortion
analyzer
connected
across
the
output load (8-ohm), set the analyzer on the 30 VAC
scale.
. Turn the analyzer on and increase the audio oscillator
output to 180 mV. The AC VTVM should read 14.1V
AC or more
(INCASE
BLA-530/A530)
(17 V AC or
more INCASE BLA-545/A-545)
E. HARMONIC DISTORTION TEST
1. Set the frequency
of the audio
oscillator and the
distortion analyzer to 20 kHz.
. Set the controls of the analyzer for voltage measure-
ment on the 30 voit scale.
Adjust
the
audio
oscillator
output
level
until
the
analyzer meter indicates 14.1V AC.
(INCASE BLA-530/A530)
(17V
AC or more INCASE BLA-545/A-545)
Switch
the
distortion
analyzer
to Set
Level
and
adjust SENSITIVITY
for full scale reading on O~0.3%
scale.
. Measure
the
total
harmonic
distortion
with
the
analyzer and verify it is less than 0.1%.
NOTE:
Any
parasitic oscillation in the amplifier will be
displayed on the oscilloscope when capacitance is
switched into the load.
6
10.
. Switch the distortion analyzer back to SET LEVEL.
(Do not readjust sensitivity of analyzer.)
. Change the frequency of the audio oscillator and dis-
tortion
analyzer
to
1 kHz.
Adjust
audio
oscillator
output for a full scale reading on the0 ~0.3%
scale.
Measure the distortion, verifying it is no greater than
0.1%.
Repeat
steps 7 and 8, changing frequency to 20 Hz.
Distortion should be no more than 0.1%.
Check for parasitic oscillation; there should be none.