Kenwood TH-235A Service Manual page 32

144mhz fm transceiver
Hide thumbs Also See for TH-235A:
Table of Contents

Advertisement

TH-235A/E/234
Common section
ADJUSTMENT
Item
Condition
Measurement point
Adjustment
Specification
Test
Unit
[Terminal]
Unit | Parts
Methoud
Equipment
1.Setting
1)Connect the DC IN
to the set.
Power supply : DC IN 12.0V
2.Line mode | 1)Turn on the SET with Shorting | Power
No indication error in ail
set up
the test point T.
meter
Check
indication on.
F—counter
LAMP on (Both side).
ojoctrnon
CH: Oe MM, A. 234
OVM
.
147.975MHz + 5OHZ : K
43 T E "
ANT
RF
TC1
Adjust
173.900MHz +50Hz : M, A, 234
Transmit
145.975MHz + 50Hz: T, E
4.Lock volt.
CH:
01:K
check (TX Lo}
24:M, A, 234
Check
1.8~2.8V:K, T,E
41:T,E
ec
1.0~2.0V : M, A, 234
Transmit
§.Lock volt.
CH: 04:K
check (RX Lo)
24:M, A, 234
Check
1.0~2.0V
44:T,E
6.Lock volt.
CH: 03:K
check (TX Hi)
25:M, A, 234
2.1~3.5V:K,T,E
43:T,£
RF | Lv
Check
5.2~8.2V:M, A, 234
Transmit
7.Lock volt.
CH:
05:K
check (RX Hi}
25:M, A, 234
Check
4.0~6.2V
45:T,E&
8.Tuning volt.
TP2 | RF | VR2
Adjust
3.74 0.1V
Adjustment
9.BPF
CH: 01: K
Spectrum
L25
wore
a
m 'e 234
analyzer
ANT
RF
et
Adjust
Refer to the follow waveform
TG :-40dBm
REF -16.4d8m
ATT 1048
A_write
B_write
5dB/
|
4 MKR
CENTER
8.00 MHz
144.00] MHz
A
—1,171dB
y
N
4
N
f
\
VA
N
RBW
A
\
100 kHz
7
vBW
N
1 kHz
N
SWP
200ms
CENTER 144.00MHz
SPAN 50.0 MHz
Transmitter section
1.Hipower
| CH: 08 :K
Power
Adjustment
28 : M, A, 234
meter
Check
More than 5.5W
:
ANT
48 :T,E
DC.A
;
5.0 + 0.1W
Transmit
RF
VR1
Adjust
Less than 1.7A
32