Lamona Arroscia TAP8321 Manual
Lamona Arroscia TAP8321 Manual

Lamona Arroscia TAP8321 Manual

3 in 1 hot water tap

Advertisement

Quick Links

TAP6000-2, TAP6002-2, TAP6004-2, TAP8321
Arroscia 3 in 1 Hot Water Tap

Guarantee (UK only):

Your tap has the benefit of a comprehensive manufacturer's guarantee, details of which are shown on your Proof of Purchase
Document. Any claim during the period of the guarantee must be accompanied by the Proof of Purchase. The product must be
correctly installed and operated in accordance with the manufacturer's instructions and used for normal domestic purposes. This
guarantee does not cover accidental damage, misuse or alterations which are likely to affect the product. The guarantee is invalid if the
product is tampered with, or repaired by any unauthorized person. The guarantee in no way affects your statutory or legal rights.

Care Instructions for your Kitchen Sink Mixer:

To maintain the appearance of this tap, ensure that it is regularly cleaned only using a clean, soft damp cloth. A solution of warm water
and a mild liquid detergent may be used where necessary, and then the fitting rinsed thoroughly and wiped dry. Any other cleaning
action will invalidate your warranty.
Abrasive cleaners, scouring cleaners and acidic cleaners must not be used under any circumstances. Avoid contact with all solvents
(including chlorinated solvents, ketones or acetones as these may result in surface deterioration or etching). Also avoid contact with
any harsh household chemicals such as oven cleaners, drain cleaners, rust removers, paint strippers and toilet bowl cleaners, bar
keepers friend or Brasso.
Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow
performance.

Important Technical Data:

Minimum operating pressure (hot): 0.75 bar
Maximum operating pressure: 5.5 bar*
Flow characteristics: Domestic Hot & Cold share
outer single flow spout.
Boiled water: Through centre spout channel.
*If these temperatures or pressures are exceeded, even for short periods, damage can result. In these instances a thermostatic mixing
or pressure reducing valve should be installed.
This product is manufactured in accordance with recognised European standards. Please ensure that your kitchen mixer is fitted in
accordance with Local Water Byelaws. Where hot and cold water mix within the tap, then suitable non return (check) valves
should be installed to both the hot and cold supplies to prevent backflow, a preinstalled non return valve on the cold supply flexi
hose (B6) is already supplied (see instructions key).
Hot and cold supply pressures should be as closely balanced as possible for best results. Supply pipes should maintain the maximum
diameter until immediately before the fitting. The differential between the hot and cold water supply temperatures should be sufficient to
allow correct mixing function.
These installation guidelines have been prepared for your direction and you must exercise due care at all times. We do not accept
responsibility for problems that may occur through improper installation. Whilst assembling the tap take care not to accidentally loosen
any factory fixed assemblies.
This tap has been 100% assembly tested; therefore you may expect a small residual amount of water to remain in the tap when
delivered. Any water marks can be removed using the above care advice.

Installation Preparation

Before installing the new mixer it is essential that you thoroughly flush through the supply pipes in order to remove any
remaining solder, swarf or impurities from your system. Failure to carry out this simple procedure could cause problems or
damage to the workings of the mixertap or boiler.
We recommend installing particle filters (not shown) and isolation valves (B5) to both the hot and cold feed pipes in an
accessible position. This will help to prevent premature failure of the valves and ease any future maintenance.
Ensure you have suitable domestic hot and cold water pressure before installing this product (see technical data
information).
All parts should be removed from their packaging and inspected for any transport damage and that all parts are present prior to
installation.
Shut off your water heating system and ensure that your mains stopcock is closed. Open the lowest hot and cold taps in the house and
allow the water to run until fully stopped.
If replacing an existing tap, remove the tap & clean the end of the feed pipes using wire wool, the tap hole area should be
dirt and sealant. Loosely position the tap and tail pipes to check if any alteration to the existing pipework is required, if this
is the case do this now.
Minimum operating pressure (cold): 1.5 bar
Maximum domestic hot water temperature: 70°C*
Recommended domestic hot water temperature: 46°C
07-21
for more
free from

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Arroscia TAP8321 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lamona Arroscia TAP8321

  • Page 1 TAP6000-2, TAP6002-2, TAP6004-2, TAP8321 07-21 Arroscia 3 in 1 Hot Water Tap Guarantee (UK only): Your tap has the benefit of a comprehensive manufacturer’s guarantee, details of which are shown on your Proof of Purchase Document. Any claim during the period of the guarantee must be accompanied by the Proof of Purchase. The product must be correctly installed and operated in accordance with the manufacturer’s instructions and used for normal domestic purposes.
  • Page 2 Parts and Contents Key Description Mixer tap Base plinth Base plinth seal Sink or worktop (max. 50mm) White triangular plate (for use with steel sinks only) Lower gasket Metal horseshoe Fixing stud Fixing nut Domestic hot in (from mains feed) red banded flexible hose M10 x ½”BSPM (15mm) 15mm olive 15mm nut...
  • Page 3 Install the tap: This diagram shows the view of the base of the tap (A1) with the 98°C water handle to the left of the body. ⚠ YOU MUST CAREFULLY RESPECT THE INLETS AND OUTLETS AS SHOWN Install the tap: Screw the fixing stud (A8) into base of tap (A1) as shown on the diagram.
  • Page 4 Install the Filter: Find a suitable place to mount the filter cartridge (C7) under the sink, it must be mounted vertically, easily accessible (to be changed periodically), away from any heat source or electrical connections and close enough not to exceed the available length of the ¼”...

This manual is also suitable for:

Arroscia tap6000-2Arroscia tap6002-2Arroscia tap6004-2

Table of Contents