Bosch PVQ731F15E Information For Use page 17

Induction hob with integrated ventilation system
Hide thumbs Also See for PVQ731F15E:
Table of Contents

Advertisement

2.
ATTENTION!
Falling grease filters may damage the hob below.
Grip below the grease filter with one hand.
Remove the grease filter.
Grease may accumulate in the bottom of the
container. Hold the grease filter level to prevent
grease from dripping out.
3.
Remove the four odour filters or acoustics filters,
and dispose of them properly.
Insert two odour filters or acoustics filters into the
4.
left and right of the appliance and slide them for-
wards.
Insert the other odour filters or acoustics filters into
5.
the left and right of the appliance.
Insert the grease filter.
6.
Resetting the saturation indicator
Requirement: After the appliance is switched off,
​ ⁠   lights up.
Replace the odour filter. → Page 16
1.
Press and hold
​ ⁠ until an audible signal sounds.
2.
a The ​ ⁠ display stops lighting up. The saturation indic-
ator for the odour filters is reset.
20.6 Cleaning the grease filters
Grease filters filter the grease from the cooking vapour.
To keep it in good working order, you must clean the
grease filter regularly.
WARNING ‒ Risk of fire!
Fatty deposits in the grease filters may catch fire.
Never operate the appliance without a grease filter.
Clean the grease filters regularly.
Never work with naked flames close to the appli-
ance (e.g. flambéing).
Cleaning and servicing en
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pvq f1 series

Table of Contents