Download Print this page

DeWalt DCF961N Original Instructions Manual page 34

Hide thumbs Also See for DCF961N:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 26
EnGLIsh
To select forward rotation, release the trigger switch and
depress the for ward/re verse control button on the right side of
the tool.
To select reverse, release the trigger switch and depress the
forward/reverse control button on the left side of the tool.
The centre position of the control button locks the tool in the off
position. When changing the position of the control button, be
sure the trigger is released.
nOTE: The first time the tool is run after changing the direction
of rotation, you may hear a click on start‑up. This is normal and
does not indicate a problem.
Worklight (Fig. A, D)
The worklight 
 7 
is activated when the variable speed trigger 
is depressed. Pressing the worklight switch 
cycle through low illumination, high illumination, and off.
nOTE: The worklight is for lighting the immediate work surface
and is not intended to be used as a flashlight.
Proper Hand Position (Fig. E)

WARNING: To reduce the risk of serious personal injury,
ALWAYS use proper hand position as shown.

WARNING: To reduce the risk of serious personal
injury, ALWAYS hold securely in anticipation of a
sudden reaction.
Proper hand position requires one hand on the main handle 
Usage (Fig. A)

CAUTION: Ensure fastener and/or system will withstand
the level of torque generated by the tool. Excessive torque
may cause breakage and possible personal injury.
1. Place the accessory on the fastener head. Keep the tool
pointed straight at the fastener.
2. Press variable speed trigger switch 
Release variable speed trigger switch to stop operation.
Always check torque with a torque wrench, as the fastening
torque is affected by many factors including the following:
-
Voltage: Low voltage, due to a nearly discharged
battery, will reduce fastening torque.
-
accessory size: Failure to use the correct accessory size
will cause a reduction in fastening torque.
Bolt size: Larger bolt diameters generally require
-
higher fastening torque. Fastening torque will also vary
according to length, grade, and torque coefficient.
-
Bolt: Ensure that all threads are free of rust and other
debris to allow proper fastening torque.
-
Material: The type of material and surface finish of the
material will affect fastening torque.
Fastening time: Longer fasten ing time results in
-
increased fastening torque. Using a longer fastening
time than recommended could cause the fasteners to
be overstressed, stripped or damaged.
MAINTENANCE
Your power tool has been designed to operate over a long
period of time with a minimum of maintenance. Continuous
32
 1 
 8 
 repeatedly will
 8 
.
 1 
to start operation.
satisfactory operation depends upon proper tool care and
regular cleaning.

WARNING: To reduce the risk of serious personal
injury, turn tool off and disconnect battery pack
before making any adjustments or removing/
installing attachments or accessories. An accidental
start-up can cause injury.
The charger and battery pack are not serviceable.
Lubrication
Your power tool requires no additional lubrication.
Cleaning

WARNING: Electrical shock and mechanical hazard.
Disconnect the electrical appliance from the power source
before cleaning.

WARNING: To ensure safe and efficient operation,
always keep the electrical appliance and the ventilation
slots clean.

WARNING: Never use solvents or other harsh chemicals
for cleaning the non-metallic parts of the tool. These
chemicals may weaken the materials used in these parts.
Use a cloth dampened only with water and mild soap.
Never let any liquid get inside the tool; never immerse any
part of the tool into a liquid.
Ventilation slots can be cleaned using a dry, soft non‑metallic
brush and/or a suitable vacuum cleaner. Do not use water or
any cleaning solutions. Wear approved eye protection and an
approved dust mask.
Optional Accessories

WARNING: Since accessories, other than those offered
by D
WALT, have not been tested with this product, use
e
of such accessories with this tool could be hazardous.
To reduce the risk of injury, only D
accessories should be used with this product.
Consult your dealer for further information on the
appropriate accessories.
Protecting the Environment
w
Separate collection. Products and batteries marked
with this symbol must not be disposed of with
normal household waste.
Products and batteries contain materials that can
be recovered or recycled, reducing the demand for raw
materials. Please recycle electrical products and batteries
according to local provisions. Further information is available at
www.2helpU.com.
Rechargeable Battery Pack
This long‑life battery pack must be recharged when it fails to
produce sufficient power on jobs that were easily done before. At the
end of its technical life, discard it with due care for our environment:
Run the battery pack down completely, then remove it from
the tool.
Li‑Ion cells are recyclable. Take them to your dealer or a
local recycling station. The collected battery packs will be
recycled or disposed of properly.