Hitachi LH1 Series Basic Manual page 47

Table of Contents

Advertisement

Chapter 4
[db-01] to [db-64]
Code/Name
db-01
Program download monitor
db-02
Program No. monitor
db-03
Program counter (Task-1)
db-04
Program counter (Task-2)
db-05
Program counter (Task-3)
db-06
Program counter (Task-4)
db-07
Program counter (Task-5)
db-08
User monitor-0
db-10
User monitor-1
db-12
User monitor-2
db-14
User monitor-3
db-16
User monitor-4
db-18
Analog output monitor YA0
db-19
Analog output monitor YA1
db-20
Analog output monitor YA2
db-21
Analog output monitor YA3
db-22
Analog output monitor YA4
db-23
Analog output monitor YA5
Code/Name
db-30
PID1 feedback value 1 monitor
db-32
PID1 feedback value 2 monitor
db-34
PID1 feedback value 3 monitor
db-36
PID2 feedback value monitor
db-38
PID3 feedback value monitor
db-40
PID4 feedback value monitor
db-42
PID1 target value monitor
db-44
PID1 feedback value monitor
db-50
PID1 output monitor
db-51
PID1 deviation monitor
db-52
PID1 deviation 1 monitor
db-53
PID1 deviation 2 monitor
db-54
PID1 deviation 3 monitor
db-55
PID2 output monitor
db-56
PID2 deviation monitor
db-57
PID3 output monitor
db-58
PID3 deviation monitor
db-59
PID4 output monitor
db-60
PID4 deviation monitor
db-61
Current PID P-Gain monitor
db-62
Current PID I-Gain monitor
db-63
Current PID D-Gain monitor
db-64
PID feedforward monitor
Range (unit)
00(Program is not
installed)/
01(Program is
installed)
0000 to 9999
1 to 1024
-2147483647
to +2147483647
0.00 to 100.00%
Range (unit)
-100.00 to 100.00(%)
(it also depends on [AH-04],
[AH-05], [AH-06])
-100.00 to 100.00(%)
(it also depends on [AJ-04],
[AJ-05], [AJ-06])
-100.00 to 100.00(%)
(it also depends on [AJ-24],
[AJ-25], [AJ-26])
-100.00 to 100.00(%)
(it also depends on [AJ-44],
[AJ-45], [AJ-46])
-100.00 to 100.00(%)
(it also depends on [AH-04],
[AH-05], [AH-06])
-100.00 to +100.00(%)
-200.00 to +200.00(%)
-100.00 to +100.00(%)
-200.00 to +200.00(%)
-100.00 to +100.00(%)
-200.00 to +200.00(%)
-100.00 to +100.00(%)
-200.00 to +200.00(%)
0.0 to 100.0
0.0 to 3600.0(s)
0.00 to 100.00(s)
0.00 to 100.00(%)
4-7
For parameter configuration
Code/Name
dC-01
Inverter load type status
dC-02
Rated current monitor
dC-07
Main speed input source
monitor
dC-08
Sub speed input source
monitor
dC-10
RUN command input source
monitor
dC-15
Cooling fin temperature
monitor
dC-16
Life assessment monitor
dC-20
Accumulated number of starts
monitor
dC-21
Accumulated number of
power-on times monitor
dC-22
Accumulated RUN time
monitor
dC-24
Accumulated power-on time
monitor
dC-26
Accumulated cooling-fan run
time monitor
dC-37
Icon 2 LIM monitor
*2)
dC-38
Icon 2 ALT monitor
*2)
dC-39
Icon 2 RETRY detail monitor
dC-40
Icon 2 NRDY detail monitor
dC-45
IM/SM monitor
dC-50
Firmware ver. Monitor
dC-53
Firmware Gr. Monitor
*1)00(disabled)/01(Ai1)/02(Ai2)/03 (Ai3)/04(Ai4)/05(Ai5)/06(Ai5)
07(Multi-speed 0)/08(auxiliary speed)/09 to 23(Multi-speed1 to 15)/
24(JG[AG-20])/25(RS485)/26(option-1)/27(option-2)/28(option-3)/
29(Pulse train input(internal))/30(Pulse train input(option))/31(EzSQ)
32(PID)/33(MOP-VR)/34(AHD retention speed)/
*2)This parameter is only effective when using the liquid crystal operator
VOP(option).
*3) The parameter is about Safety function,is not suitable for LH1 series.
[dC-01] to [dE-50]
Range (unit)
00(Very Low duty)/
01(Low duty)/
02(Normal duty)
0.0 to 6553.5(A)
01 to 34 *1)
00 to 06,08,25 to 33 *1)
00([FW]/[RV] terminal)/
01(3-wire)/
02(Keypad's RUN key)
03(RS485)/04(Option1)/
05(Option2)/06(Option3)
-20.0 to 200.0(°C)
LL to HH
[L:Normal/H:Fatigued]
[Left](FAN lifespan)
[Right](board capacitor life
span)
1 to 65535(cycles)
1 to 1000000(hr)
00(Other than below )/
01(OC suppress)/
02(OL restriction)/
03(OV suppress)/
04(TRQ Limit)/
05(Freq Limit)/06(Min. Freq)
00(Other than below )
01(OL notice )
02(Motor thermal notice)
03(Controller thermal
notice)
04(Motor overheating
notice)
00(Other than below)
*2)
01(Waiting for retry)
02(Waiting for restart)
00(Other than below )
*2)
(Output terminal 007[IRDY]= ON,
When the state is other than
the following )
01(Trip occurrence)
02(Power supply error)
03(Resetting)
04(STO) *3) / 05(Standby)
06(Data Warning, etc)
07(EzSQ Sequence error)
08(Free run) / 09(Forced stop)
00 (IM selected)/
01 (SM selected)
00.00 to 99.99
00(Standard)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lh1-075hfc

Table of Contents