4.3.
Attach the hose with the ball valve adaptor (fig.3.1) to the base of the reservoir tank.
5. AIR SUPPLY
The recommended hook-up is shown in fig.4.
5.1.
Ensure the air valve is in the "Off" position before
connecting to the air supply.
5.2.
You will require an air pressure of 0.45bar (7psi).
WARNING! Ensure the air supply is clean and does not
exceed pressures specified in these Instructions. Too high
an air pressure and/ or unclean air will shorten the drainer
life due to excessive wear, and may be dangerous, causing
damage and/or personal injury.
5.3.
Drain the air tank daily. Water in the air line may damage
the drainer.
5.4.
Clean the air inlet filter screen weekly.
5.5.
Line pressure should be increased to compensate for
unusually long air hoses (over 8 metres). The minimum
hose diameter should be 10mm I.D. and fittings must have
the same inside dimensions.
5.6.
Keep hose away from heat, oil and sharp edges. Check hoses for wear, and make certain that all connections are secure.
6. OPERATION
WARNING! Ensure that you read, understand and apply the safety instructions in Section 1.
6.1.
OPERATION
6.1.1.
To raise or lower the drain pan, slacken off the handwheel (fig.5.1) while supporting the weight of the drain pan, move drain pan to
the correct height and then tighten the hand wheel.
WARNING! Oil should be removed when hot (70-80°C). Keep hands, face and body protected using suitable personal protective
equipment (PPE).
6.1.2.
Drain the oil into the drain pan ensuring that the drain pan valve is open (fig.5.2) and the ball valve tap at the base of the tank is
closed (fig.3.1).
6.1.3.
When draining is complete, lower oil pan before moving drainer.
6.2.
EMPTYING
6.2.1.
Ensure that drain pan valve (fig.6.2) is closed and hand wheel (fig.6.1) is tight.
6.2.2.
Attach the end of the drain hose to a suitable waste oil container (fig.6).
6.2.3.
Open ball valve tap (fig.6.5).
6.2.4.
Connect air supply at a pressure of 0.45bar to coupling (fig.6.4) and open valve 3 (fig.6.3).
6.2.5.
After the fluids have been transferred from the tank close valve 5 (fig.6.5).
6.2.6.
Disconnect from air supply and vent any pressure remaining in the tank by opening drain pan valve (fig 6.2) and/or air valve
2
fig.5
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted,
taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product
becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and
dispose of the product and fluids according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call
our technical team on technical@sealey.co.uk or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
fig.6
1
sales@sealey.co.uk
Original Language Version
1
2
3
4
5
www.sealey.co.uk
REGISTER YOUR
PURCHASE HERE
AK458DX.V5
Issue 1
12/04/23
fig.4

Advertisement

loading