Diamond EVJ805 Installation, Usage And Maintenance Manual

Blast chiller

Advertisement

Quick Links

06/2018
Mod: GTP-3/LD
Production code: 19048717

Advertisement

Table of Contents
loading

Summary of Contents for Diamond EVJ805

  • Page 1 06/2018 Mod: GTP-3/LD Production code: 19048717...
  • Page 2 INSTALLATION, USAGE AND MAINTENANCE MANUAL EVJ805: BLAST CHILLER...
  • Page 3: Table Of Contents

    INSTALLATION, USAGE AND MAINTENANCE MANUAL: BLAST CHILLER CONTENTS INSTALLATION............................27 SITING ..............................27 CLEANING ............................27 WIRING ............................... 28 GENERAL MEASUREMENTS......................28 USE ................................30 – ENVIROMENTAL DATA ........................30 – CONSTRUCTION DATA ......................... 30 – UTILIZACIÓN ..........................30 –...
  • Page 4: Installation

    INSTALLATION, USAGE AND MAINTENANCE MANUAL Before starting the cooler up, we would like to thank you for the confidence you have placed in us on purchasing this machine, and recommend you read and follow the steps detailed in the instructions. This manual is designed to offer the information necessary for the installation, start-up, and maintenance of the Temperature Coolers.
  • Page 5: Wiring

    1.2 WIRING Before plugging the appliance into the socket, check that the network voltage and frequency correspond with those indicated on its' nameplate. Also check that the section of the electricity socket is appropriate for the consumption it is going to withstand. It is essential that the electrical installation where it is going to be connected has an EARTHING SOCKET, in addition to the appropriate protection of the magneto-thermal switch and differential (we recommend 30 mA.)
  • Page 6 - 5 GN 1/1 - 10GN 1/1...
  • Page 7: Use

    2.0 – ENVIROMENTAL DATA Room Temperature. The production data have been carried out in a technical laboratory with the following environmental conditions: 38 ºC in the premises Noise level Leq in the point with noise level at 1 metre and in operating conditions <70 dB(A) Lpc at 1 metre in operating conditions <130 dB(C) The measurements of the acoustic tests have been carried out according to ISO 230-5, in a rectangular shaped exposure room without sound-absorbent treatments.
  • Page 8: Production

    During the cooling cycle: Do not open the door unit it has ended. Do not wrap the product or close the trays. Using trays with a height of over 40 mm is not recommended. The thickness of the product on the tray is compact from 2 to 2.5 cm. Using stainless steel or aluminium containers is recommended.
  • Page 9: Power Failure

    The upload completes, the device will be in the state it was in before being de-energized, i.e.: - In the Home screen without any message of supply interruption; - In cycle execution, with message POWER FAILURE to indicate the lack of power. 3.0 POWER FAILURE If there is a power interruption when there is no function, upon restoration of the power supply device reproposing the status to be before the interruption.
  • Page 10: Icons

    From Home screen: gives access to the machine set-up menu Within a menu: allows navigation downwards During a setting: decrements the value of the size that you want to modify From Home screen: gives access to the selection menu of special cycles of the machine Within a menu: allows navigation upwards During a setting: increases the value of the size that you want to modify Short press: Start the selected function or gives access to the page of the selected menu...
  • Page 11: Settings

    Curing cycle ice cream running Defrost cycle in progress Number of the current phase Chilling/freezing Cycle successfully completed Chilling/freezing Cycle does not successfully completed – SETTINGS OVERVIEW You access the list of settings by pressing from the Home screen LANGUAGES You can choose between English, French, German, Spanish, Portuguese, Simplified Chinese, Traditional Chinese.
  • Page 12: Parameters

    To return to the previous screen from this menu, press the key PARAMETERS To view the parameters from the menu it is necessary to insert previously password -17 or-19 using the key to change the value of the parameters, select the desired parameter and with the key to make it editable;...
  • Page 13: Functions

    – FUNCTIONS OPERATING CYCLES The device is able to manage the following cycles of chilling and freezing: Chilling temperature cycle and conservation Chilling hard temperature cycle and conservation Chilling and conservation Chilling hard time cycle and conservation - Freezing temperature cycle and conservation - Soft freezing temperature cycle and conservation - Freezing time cycle and conservation - Freezing soft cycle time cycle and conservation...
  • Page 14: Pre-Cooling

    During the execution of the cycle, the display will show the most significant facts: When the refrigerator system is active, icon comes on compressor in top left; - When it is running a recipe, the blue arrows are alternated to the name of the recipe; - When defrosting is in progress, appears at the top of the writing "defrost"...
  • Page 15 Example of reducing cycle at a temperature (skewer), addition of hard phase, quick change of setpoint chamber for the phase and soft start cycle. Example of deep freezing cycle at a temperature (skewer), conversion to cycle time, quick change of the duration of the freezing cycle and start cycle.
  • Page 16: Defrost Manual

    The preservation phase is infinite and has only completed by pressing the key for 2 seconds. The defrost cycles are always enabled during a conservation. During the execution of a cycle by pressing the key, it is possible to access advanced page where you can change the setpoint of work for the current cycle and display all the internal states of the machine.
  • Page 17: Hardening Ice Cream

    The flushing cycle begins with the removal step. When the temperature detected by the needle probe reaches the temperature at end of Chilling, the device will automatically switch to the maintenance. The temperature at the end of Chilling also represents the setpoint of the work during the maintenance.
  • Page 18: Recipes

    RECIPES The recipes are programs pre-attached ready to use that propose a series of cycles that are optimized for the type of dish. Recipes can be changed before the start of the cycle, but may not be saved or overwritten. Access the menu special cycles from key and select recipes to view the list of Chilling programs/default freezing available.
  • Page 19: Alarms

    Quickfreezing by needle probe Step 1 Set Chamber 0°C Set needle 3°C Step 2 Set Chamber -12°C Set needle -3°C Fase 3 Set Chamber -30°C Set needle -18°C Conservation Set Chamber -20°C – ALARMS The alarms will be displayed on the Home page if the effect is to interrupt or not to activate the cycle; if they are such as to allow the continuation of the current cycle will...
  • Page 20 Probe Error chamber. Remedies: Check the value of parameter P0 Check the integrity of the probe Check the connection device-probe Check the temperature of the chamber. The main consequences: If the error occurs during the status "stand-by", will not be allowed to initiate any THE CHAMBER cycle of operation PROBE...
  • Page 21: Usage Precautions

    Temperature alarm maximum alarm (HACCP). Remedies: Check the temperature of the chamber HIGH The main consequences: TEMPERATURE The device will store the alarm The output of the alarm will be activated. Alarm Chilling at a temperature or freezing at a temperature not concluded within the maximum duration alarm (HACCP).
  • Page 22: Prick Probe (Optional)

    It is essential to disconnect the appliance if you are going to clean with water. Panels should not be moved to access electrical components except by technical staff authorised to carry out maintenance and repair operations The inside of the cooler should be cleaned with great care. 8.1 PRICK PROBE (optional) It is a frequently used component.
  • Page 23: Testing And Guarantee

     Condenser cleaning: When cleaning, be careful not to bend the condenser aluminium ribs, as on the contrary the air will not come through and will not condense, causing serious damage to the appliance and its repair guarantee will be made void. ...
  • Page 24 ESQUEMA ELÉCTRICO - ELECTRICAL SCHEMATIC Abatidor de temperatura 3, 5 GN EVJ-805 Blast chiller EVJ-805 ESQUEMA ELÉCTRICO - ELECTRICAL SCHEMATIC Abatidor de temperatura 10 GN EVJ-805 Blast chiller EVJ-805...

This manual is also suitable for:

Gtp-3/ld

Table of Contents