Download Print this page

Siemens JG Installation Instructions Manual

Circuit breaker, 600vdc, frame/caja base

Advertisement

Quick Links

s
Circuit Breaker, 600VDC
Interruptor, Caja Base 600VDC
Disjoncteur, de base 600VDC
Installation Instructions / Instructivo de Instalación
Hazardous Voltage
Hazardous Voltage
Will cause death or serious injury
Will cause death or serious injury
Turn off and lock out all power supplying this device before
Turn off and lock out all power supplying this device before
working on this device.
working on this device.
Replace all covers before power supplying this device is
Replace all covers before power supplying this device is
turned on.
turned on.
Use only with Siemens certified Components.
Utilizar únicamente con componentes certificados de Siemens.
A utiliser uniquement avec les composants certifiés Siemens .
NOTICE:
[ AVISO: ]
Only Qualified Personnel should work on this equipment, after becoming
thoroughly familiar with all warnings, safety notices and maintenance
procedures contained here in and on the devices.
A Qualified person is one as defined in NFPA 70.
[Solamente personal calificado debe trabajar en este equipo, después de
familiarizarse a fondo con todas las advertencias, avisos de seguridad, y
procedimientos de mantenimiento contenidas aquí y en los dispositivos.
Una persona calificada es una como se define en el NFPA 70.]
NOTE - These instructions do not purport to cover all details or variations in
equipment, or to provide for every possible contingency to be met in
connection with installation, operation or maintenance. Should further
information be desired or should particular problems arise, which are not
covered sufficiently for the purchaser's purposes, the matter should be
referred to the local Siemens sales office. The contents of this instruction
manual shall not become part of or modify any prior or existing agreement,
commitment or relationship. The sales contract contains the entire obligation
of Siemens. The warranty contained in the contract between the parties is
the sole warranty of Siemens. Any statements contained herein do not create
new warranties or modify the existing warranty.
Trademarks - Unless otherwise noted, all names identified by ® are
registered trademarks of Siemens AG or Siemens Industry, Inc. The
remaining trademarks in this publication may be trademarks whose use by
third parties for their own purposes could violate the rights of the owner.
3VL4625-2KN30-0AA0
3VL4630-2KN30-0AA0
3VL4635-2KN30-0AA0
3VL4640-2KN30-0AA0
M6 X 100mm
3VL9500-8SA40
8 0 6 9 6 2 A 0 2
Tensión peligrosa.
Tensión peligrosa.
Puede causar la muerte o lesiones graves.
Puede causar la muerte o lesiones graves.
Desenergice totalmente antes de instalar o darle servicio.
Desenergice totalmente antes de instalar o darle servicio.
Reemplace todas las barreras y cubiertas antes de
Reemplace todas las barreras y cubiertas antes de
energizar el interruptor.
energizar el interruptor.
Cal. ISO 6789
1 / 7
Euro Order No.
U.S. Cat. No.
HJC3B_ _0 3VL46_ _-2KN30-0AA0
HLC3B_ _0 3VL48_ 0-2KN30-0AA0
Frame: JG, LG - Type HJGD, HLGD
Caja Base: JG, LG - Tipo HJGD, HLGD
Tension dangereuse.
Tension dangereuse.
Danger de mort ou risque de blessures graves.
Danger de mort ou risque de blessures graves.
Couper l'alimentation de l'appareil et barrer avant de
Couper l'alimentation de l'appareil et barrer avant de
travailler.
travailler.
Remplacez touts les couverts avant que
Remplacez touts les couverts avant que
l'approvisionnement de pouvoir soit alimenté.
l'approvisionnement de pouvoir soit alimenté.
1/4"
Ø.08 – .10 x 5.9
[ Ø 2 - 2.5 mm X 150 mm ]
HLC3B400
HLC3B500
HLC3B600
1/4 – 20 X 4.0
MSKL4
3VL4840-2KN30-0AA0
3VL4850-2KN30-0AA0
3VL4860-2KN30-0AA0
M6 X 100mm
3VL9500-8SA40
HJC3B250
HJC3B300
HJC3B350
HJC3B400
1/4 – 20 X 4.0
MSKL4
I.L. No. 806962A02
7/16"
10mm

Advertisement

loading

Summary of Contents for Siemens JG

  • Page 1 Siemens sales office. The contents of this instruction 3VL4840-2KN30-0AA0 manual shall not become part of or modify any prior or existing agreement, 3VL4850-2KN30-0AA0 commitment or relationship.
  • Page 2 [ 6 – 9 mm ] “W” = ≤ 1.26 [ 32 mm ] JG - T = .20 - .40 [ 3 – 10 mm ] LG - T = .17 - .34 [ 3 – 10 mm ] Trip Unit –...
  • Page 3 4.52 [115] 1.75 [44.5] 4.19 [106.5] 1.75 [44.5](4P) 1.75 [44.5] 4.00 [101.5] JG ONLY .19 [5] JG FRAME .25 [6.5] LG FRAME Ø.33 [Ø8.3] JG FRAME Ø.41 [Ø10.5] LG FRAME .19 [5] JG FRAME .96 [24.5] .22 [5.6] LG FRAME 1.31 [33]...
  • Page 4 See page 5 Option: [ Ver la página 5 ] [ Opción: ] “A” 6 mm 133 lb. In. [ 15 Nm ] 1 / 2“ “D” See page 5 Option: [ Ver la página 5 ] [ Opción: ] “C”...
  • Page 5: Wire Connector

    Hazardous Voltage Hazardous Voltage Tensión peligrosa. Tensión peligrosa. Tension dangereuse. Tension dangereuse. Will cause death or serious injury Will cause death or serious injury Puede causar la muerte o lesiones graves. Puede causar la muerte o lesiones graves. Danger de mort ou risque de blessures graves. Danger de mort ou risque de blessures graves.
  • Page 6 UL 486A - 486B Torque Req. [ esfuerzo de Wire Stranding Wire Connector Wire Size Wire Strip Length torsión ] [ Hebras ] [ Rango Cable ] [ Conexión del cable ] [ Quitar ] CU / AL “D” Class B Class C Cu / Al Strands...
  • Page 7 Bestell-Nr. / Order No.: 3ZX1012-0VL68-5DA1 Internet: www.siemens.de/lowvoltage/technical-assistance GWA 4NEB 1796962-10 DS 03 Technical Support: Toll Free: 1-800-241-4453 Internet: www.usa.siemens.com/powerdistribution Subject to change without prior notice © Siemens Industry Inc. 2010 Siemens Industry, Inc. , Norcross, GA 30092 U.S.A. 806962A02 7 / 7...

This manual is also suitable for:

LgHjgdHlgdHlc3b400Hlc3b500Hlc3b600 ... Show all