Download Print this page
SELTZA SeltzaHub Installation, Operation And Maintenance Manual

SELTZA SeltzaHub Installation, Operation And Maintenance Manual

Advertisement

Quick Links

Installation, Operation,
and Maintenance Guide
SeltzaHub/ SeltzaTap/ SeltzaTap Compact

Advertisement

loading
Need help?

Need help?

Do you have a question about the SeltzaHub and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SELTZA SeltzaHub

  • Page 1 Installation, Operation, and Maintenance Guide SeltzaHub/ SeltzaTap/ SeltzaTap Compact...
  • Page 2: Table Of Contents

    Table of contents 1. SeltzaHub Technical Specifications What’s included Installation Operation Maintenance 2. SeltzaTap Technical Specifications 14-15 Installation Operation Maintenance 17-18 3. SeltzaTap Compact Operation Installation, Operation, and Maintenance Guide...
  • Page 3: Seltzahub

    SELTZAHUB Tecnical Specifications Seltza water Cold water Ambient water 410mm (16 1/4”) SeltzaHub has 3 valves ont the side and the machine is 210mm (8 1/4”) at that point. 450mm (17 3/4”) 170mm (6 5/8”) Voltage 120V 60Hz Current Chilled still water capacity...
  • Page 4 SELTZAHUB What’s included? 1. SeltzaHub 2. CO2 Regulator with TR21-4 threads (SodaStream style cartridge) 3. Regulator adapter to CGA-320 (Larger style CO2 Tanks 5, 10, 20 lbs) 4. T-Stop Valve 5. Tubing as per below 6. Power Cord SeltzaHub Seltza regulator...
  • Page 5: Installation

    SELTZAHUB Installation Overall view of installation SeltzaTap Regulator Seltza water T-stop Cold water valve 5/16” 5/16” Ambient water (existing valves) CO2 cylinder (not included) 1/4” SeltzaHub Filter (not included) Installation, Operation, and Maintenance Guide...
  • Page 6 SELTZAHUB SELTZAHUB Installation Ensure the SeltzaHub is put into the Turn off cold Disconnect existing proposed installation location 24hours water from existing cold water lines from before starting up. This ensures there valve under the sink. existing valve. will be no issues with refrigerant system.
  • Page 7 5/16’ b) Turn on Main water valve. Check for leaks c) Turn on T-Stop valve Check for leaks d) Turn on Each valve on the side of SeltzaHub and wait for 5 seconds. Check each valve for leaks. Seltza water...
  • Page 8 Plug in and turn on power. Let the cooling 10 minutes after turning power on adjust the CO2 system inside the SeltzaHub cool and carbonate pressure regulator to 75 psi. Ensure no CO2 leaks for 20 minutes. You should hear the pump feed water into the machine and the compressor start up.
  • Page 9: Operation

    SELTZAHUB Operation Button functions Name and function Comments Show temperature of the cooling LED Lamp -- status of the cooling system Error: Fault of the machine (see detail below) Press for five seconds, button will start to shine, then adjust the temperature...
  • Page 10 Flow Rate Adjustment It is possible to adjust the flow rate up or down inside the SeltzaHub. This may increase the instance of E4 error codes and is not detrimental to the machine. 1. Turn off SeltzaHub 4.
  • Page 11 Do not try to fix the machine. If there are any unusual NOISE, shutdown the Noise Shutdown the machine and contact SeltzaHub, close the water inlet and gas inlets. Seltza customer support. This marking indicates that this product should Correct Disposal of this product.
  • Page 12 Applicable to all above, is that the warranties need to be approved by Seltza to ensure product was not incorrectly used, installed or claimed. False and incorrect claims will be pursued at Seltza discretion, includ- ing chargeable inspection and labour costs incurred.
  • Page 13: Seltzatap

    SeltzaTap 216mm 90cm 50mm 175mm 90 cm long 5/16 inch PE tubing Countertop hole and Blue tubing = Chilled Seltza thickness requirements White Tubing = Chilled Still Clear Tubing = Ambient Still 35mm Max Countertop thickness Faucet hole diameter is 1 3/4" (45mm) in Countertop is 1 3/8"...
  • Page 14: Installation

    SELTZATAP Installation Ensure the SeltzaHub is put into the proposed installation location 24hours before starting up. This ensures there will be no issues with refrigerant system. Turn off hot and cold Disconnect existing hot Remove faucet nut from existing faucet.
  • Page 15 May require an adapter. May require an adapter ambient water Sample image under the sink Connect the chilled sparkling, chilled still, and ambient still 5/16” tubing from SeltzaHub to SeltzaTap. T-stop valve 5/16’ Seltza water Blue Chilled water White...
  • Page 16 SELTZATAP SeltzaTap Operation Right hand lever Hot and cold water for cleaning and dishes. Water coming out of second nozzle. Left hand lever Chilled sparking water Push button on spray function on hot and cold water Chilled Still water Hose is removable Ambient Still water (will be the temperature of the main building...
  • Page 17 Changing Cartridges Sparkling water (Left Hand Cartridge) 1. Turn the water off to the faucet at the SeltzaHub valves. 2. Put a piece of painters tape between the faucet body and handle to have a clear line to line it up when reinstalling it.
  • Page 18 SELTZATAP SeltzaTap Maintenance Changing Cartridges Regular water (Right Hand Cartridge) Turn off hot and cold 1. Turn the water off to the faucet at the Hot and Cold valves below sink. (As shown.) water from existing valves under the sink. 2.
  • Page 19: Seltzatap Compact

    90cm 50mm 172mm 90 cm long 5/16 inch PE tubing Countertop hole and thickness requirements Blue tubing = Chilled Seltza White Tubing = Chilled Still Clear Tubing = Ambient Still 35mm Max Countertop thickness Faucet hole diameter is 1 3/4" (45mm) in Countertop is 1 3/8"...
  • Page 20 SELTZATAP COMPACT SeltzaTap Compact Operation Right hand lever Left hand lever Hot and cold water for Chilled sparking water cleaning and dishes. Chilled Still water Ambient Still water (will be the temperature of the main building supply water) Installation, Operation, and Maintenance Guide...