EDGE THEORY LABS 10X Health Pro Plunge Maintenance Instruction

Advertisement

The 10X Health Pro Plunge comes equipped with an Ozone (O3) sanitation system included and
pre-configured from the factory to ensure you have crystal clear and clean water for anytime you are
ready to plunge. While the Ozone system is typically very effective and normally sufficient for
residential use levels, we recommend utilizing the included Sirona Simply sanitizer to further
stabilize and sanitize the water. In normal residential use without using Sirona Simply (just Ozone),
you can expect up to 4 weeks of water life before the tub needs to be drained and refilled. However,
with Sirona Simply, the water can usually last several months. Circumstances such as multiple users
per day or users getting into the tub straight after a workout without showering can necessitate
additional water maintenance. Our recommended maintenance protocol can be found below as well
as our instructional video here >>

Initial Setup (new water)

-
Add 60cc (2 measuring spoons) of Oxidizer into water
-
Wait 15 minutes
-
Add 15cc (1/2 measuring spoon) of Sanitizer into water
-
Wait 15 minutes before entry into Tub

Weekly Maintenance

SUMMARY: There's 3 simple steps for weekly maintenance that take about 15 minutes in total. First,
check the water chemistry. Then, check the water strainer. Then, check the water filter.

STEP 1) Check Water Chemistry

-
Start by adding 30cc (1 measuring spoon) of Oxidizer for low volume (five to seven plunges
per week) or 60cc (2 measuring spoons) for high volume (greater than seven plunges per
week)
-
Wait 15 minutes
-
Immerse test strip to a depth of 6" for 2 seconds. Remove with pads face up. Shake once to
remove excess water. Wait 10 seconds and compare "San" line to color chart on back of
bottle. If Sanitizer shows below the "OK" range, add 10cc (1/3 measuring spoon). Wait 15
minutes and test again. Repeat if necessary.
-
If Alkalinity, pH, or Calcium are outside of desired range, balancers can be purchased
through our website. Of these, pH is most important to have in the right range.

STEP 2) Check Water Strainer

-
Turn off Chiller, and close Tub Valves by turning the handle perpendicular to the valve body
-
First, remove the bottom hose from the Chiller. Remove Water Strainer Enclosure by twisting
counterclockwise and check Inner Water Strainer for debris; remove any foreign materials
present. Use brillo pad or rough sponge if necessary.
-
Ensure o-ring at the base of the threads is present and free from damage before reinstalling
Water Strainer Enclosure.

STEP 3) Check Water Filter

-
To access the filter, turn the filter housing to the left if facing the back of the Chiller. Check
Water Filter condition by comparing to the diagram below. If the condition is in the "Replace"
range, or if the flow reading on the control screen reads less than 13.0 L/min, then replace

Water Maintenance Instructions

https://www.edgetheorylabs.com/pages/10x-setup

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 10X Health Pro Plunge and is the answer not in the manual?

Questions and answers

Summary of Contents for EDGE THEORY LABS 10X Health Pro Plunge

  • Page 1 Water Maintenance Instructions The 10X Health Pro Plunge comes equipped with an Ozone (O3) sanitation system included and pre-configured from the factory to ensure you have crystal clear and clean water for anytime you are ready to plunge. While the Ozone system is typically very effective and normally sufficient for residential use levels, we recommend utilizing the included Sirona Simply sanitizer to further stabilize and sanitize the water.
  • Page 2 the filter with a new one. When changing the filter, empty the water housing and refill with fresh water. Ensure both the o-ring on the lower filter housing (clear part) and in the upper filter housing (white part) are present and free from damage before reinstalling filter housing. Be sure to open the Tub Valves before turning the Chiller back on, or damage will occur! 
...

Table of Contents