9. DISASSEMBLY INSTRUCTIONS
Be sure to unplug the machine out of the outlet before disassembling and repairing the parts.
CONTROL PANEL ASSEMBLY
www.Appliantology.org
① ① Unscrew 2 screws on the back of the top plate.
② ② Pull the top plate backward and upward as shown.
③ ③ Disconnect the connectors from the Main PWB
Assembly
④ ④ Pull out the drawer and unscrew 2 screws.
⑤ ⑤ Lift the left side of the Control Panel Assembly and
pull it out.
26