Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 3
3
EN | ENGLISH
EN|ENGLISH
INDUSTRIAL DEHUMIDIFIER
DH50, DH80, DH90
MANUAL
Technical specifications
Model
DH50
Power Supply
Max. Removal Capacity,
50
L/D
Max. Power, W
900
Rated Current, A
4.0
Refrigerant
R290/200g
Product Size, mm
495*480*658 545*460*870 480*405*890
G.W., kg
32
Working Temperature, °С
Noise emissions
56 dB
Insulation Grade
Class I
Protection category
Description (Pic. 1)*
1. Control Panel;
2. Air Inlet;
3. Filter Screen;
4. Baseboard;
IMPORTANT SAFEGUARDS
This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way and understand
the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without
supervision.
If the supply cord is damaged, it must be replaced by the manufacturer or
its service agent or a similarly qualified person in order to avoid a hazard.
WARNING:
◊ Do not use means to accelerate the defrosting process or to clean,
other than those recommended by the manufacturer.
◊ The appliance shall be stored in a room without continuously
operating ignition sources (for example: open flames, an operating
gas appliance or an operating electric heater.
◊ Do not pierce or burn.
◊ Be aware that refrigerants may not contain an odor.
◊ This appliance is intended to be used by expert or trained users in
shops, in light industry and on farms, or for commercial use by lay
persons.
INSTALLATION METHODS
1. Caster installation method: Take the machine body, caster axis,
caster and screws of the packaging case, and incline the machine
body. As shown in picture 2, fix the caster axis on the machine body
with 4 screws in counter-position, and fix the caster at both sides
of the axis also in counter-position. Upon end of the fixing, put the
body upright.
2. Upper steel pipe installation method: screw down the two screws at
top of the body, turn the upper steel pipe by 180 degrees, and fix the
upper steel pipe with the screws in counter-position.
*Tip: Upon end of installation, keep the machine out of any action
for 2h before starting to use.
3. Water tank usage: You may use the water tank in two ways. I) Direct
use. When the water tank is full, the machine automatically shuts
down and enters the standby state, the LED displays the "Full Water"
signal and the hummer alarms. When the water tank is emptied and
DH80
DH90
AC 220-240V/50Hz
70
90
1300
1350
4.7
4.8
R290/280g
R290/300g
43
50
5~35
58 dB
60 dB
Class I
Class I
IP22
5. Upper Steel Pipe;
6. Shell;
7. Air Outlet;
8. Wheel;
put in place again, the dehumidifier can continue its performance. II)
Continuous drainage. As shown in Fig. 3, to restore the performance
of the water tank, you need to take out the water tank, remove the
drain plug, and install the drain pipe. Put the water tank back to its
original position, and the water pipe goes out from the side plate.
*Tip: In continuous drainage, the drainage pipe shall not be set
higher than the water tank.
WARNING:
If the power cord is damaged, it must be replaced by the professional
person from manufacturer, the maintenance department or similar
departments.
Product Introduction
Core Parts: GMCC/GREE rotating compressors adopted, of higher
performance and less power consumption than reciprocating compressor
of identical refrigerating capacity.
Tips: For physiological health of the humanity, protection of furniture and
other items indoors and energy saving, the humidity is recommended to
range from RH50% to 70%, provided no special requirements are made.
Operation Instructions for Control Panel
Button
Operation Instructions
Shift between Switch on and switch off once for each
ON/OFF
pressing
Adjust different setting values at different states
+
1. Increase the humidity value set (RH10% to 95%)
2. Increase the Timer(hour) set (00 to 24)
Adjust different setting values at different states
-
1. Decrease the humidity value set (RH10% to 95%)
2. Decrease the Timer(hour) set (00 to 24)
Short press the button to launch a cycle of
Timer
Set on/off Timer and Exit
Function Description
1. Humidity Control
When room humidity value 3% lower than set, compressor shut
down, fan delay 3 minutes and shut down; and when it's 3% higher
than the humidity value set, both fan and compressor operate.
Note
◊ When the humidity is set at the minimum value, it's defaulted to enter
the continuous dehumidifying mode
◊ Upon fault of the humidity sensor, it turns to the continuous
dehumidifying mode
◊ Upon fault of the coil sensor, it turns to the timing defrosting mode
(See the defrosting mode)
◊ When it's shut down, the fan will be closed 10s later.
2. Protection Function
◊ Once shut down, the compressor takes 3min to start. Quick start is
available for the first power-on.
◊ Power off memory: For abrupt power outage or accidental
unplugging of the plug, the system will automatically archive the
operating state right before the incident, and continue at that state
for the next power-on.
◊ Full water protection: When the water tank is full, the dehumidifier
automatically shuts down and enters the standby state, the indicator
light "Full Water" on and buzzer alarms.
3. Defrosting Mode
Defrosting
Description
mode
1. The compressor constantly run over
20 minutes, coil temperature below 0
degree constantly over 30 minutes, it
Sensor at
Automatic
starts defrosting model.
normal
Defrosting
2. Coil temperature over 5 degrees
state
constantly over 90 seconds, or
Defrosting time over 8 minutes, it
stopped defrosting mode.

Advertisement

Table of Contents
loading

Related Products for Pro-Craft DH50

This manual is also suitable for:

Dh80Dh90

Table of Contents