Advertisement

Quick Links

User Manual
WS Series
Pulse Oximeter
Please read the manual carefully before use
Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd
Page 1 / Total 29

Advertisement

Table of Contents
loading

Summary of Contents for Accurate Bio-Medical Technology WS Series

  • Page 1 User Manual WS Series Pulse Oximeter Please read the manual carefully before use Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 1 / Total 29...
  • Page 2 User Manual and the product described herein. © Copyright owned by Hunan Accurate Bio-Medical Technology Co., Ltd. Without the written permission of Accurate, no individual or organization shall reproduce, amend or translate any part of this manual.
  • Page 3 Conventions  Bold and italic: Represents chapters quoted.  [Character]: Represents character strings in the software.  →: Represents operating steps. Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 3 / Total 29...
  • Page 4: Table Of Contents

    5.3 Measurement Steps ........................15 5.4 Factors Affecting Measurement ....................15 6. Battery ................................16 6.1 Overview .............................. 16 6.1.1 Lithium Battery Charging ....................16 7. Maintenance and Cleaning ........................17 Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 4 / Total 29...
  • Page 5 8. Troubleshooting ............................19 A. Product Specifications ..........................20 Technical Description ..........................21 B. Network Security ............................23 C. EMC .................................. 24 D. Default Factory Settings ...........................29 E. Product and Accessories ..........................29 Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 5 / Total 29...
  • Page 6: Safety

     A functional tester cannot be used to assess the accuracy of the SpO probe or Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 1 / Total 29...
  • Page 7: 3Caution

    5) Venous pulse. 6) The shock, anemia, hypothermia or application of vasoconstrictors may reduce the arterial blood flow to a non-measurable level. 7) Stain exists in blood vessels. Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 2 / Total 29...
  • Page 8: 4Note

    The device belongs to Class II Down key equipment Manufacturer Date of manufacture Protect the package from The packaging box contains rain fragile items. Handle with care Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 3 / Total 29...
  • Page 9 Authorized representative accompanying documents This item is compliant with REGULATION (EU) Medical device 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL. Unique device identifier Stacking layer limit Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 4 / Total 29...
  • Page 10: Overview

    The Pulse Oximeter is intended to be used in hospital,clinical institution, helthcare community. We recommend index finger, middle finger and ring finger are suitable position for monitor. 2.1.6 Contraindications None 2.2 Appearance Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 5 / Total 29...
  • Page 11: Product Function List

    Connect the charging cable or SpO probe. 6. Watchband 7. SpO probe (model: A401-201) 2.3 Product Function List WS20A Display screen    Pulse wave  Battery level display  Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 6 / Total 29...
  • Page 12 Rechargeable  Bluetooth  Storage  ※ “” represents that the device has this function; “/” represents that the device does not have this function. Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 7 / Total 29...
  • Page 13: Preparation Before Use

    1. Prior to startup, please check whether the oximeter has any mechanical damage. 2. Make sure the remaining battery capacity is adequate. 3. Press the Power key to enter the main interface. 3.4 Shutdown Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 8 / Total 29...
  • Page 14 3. Place the main unit of oximeter still for a while (time can be set under Menu Setup); then the oximeter will shut down automatically. Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 9 / Total 29...
  • Page 15: Basic Operations

    1. Press the Confirm key to confirm the start of setting; 2. Press the Up/Down key to set the range of upper limit for PR reminder: (lower limit + 1bpm)~250bpm; Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 10 / Total 29...
  • Page 16: System Setup

    Main menu → Setting → Factory; 2. Press the Confirm key to confirm the selection; press the Up/Down key to select the option, and press the Confirm key to confirm the modification; Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 11 / Total 29...
  • Page 17: Review

    4.9 Main Unit State Indication  When the probe is not inserted after the SpO main unit is turned on, the state indication is “No Senser”; Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 12 / Total 29...
  • Page 18  When the probe is inserted after the SpO main unit is turned on, the state indication is “Testing...”. Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 13 / Total 29...
  • Page 19: Spo Measurement And Information

     When the patient has the hypoxia tendency, the blood sample should be analyzed so as to completely know the patient’s condition.  Avoid using the oximeter when MRI equipment is used; otherwise, the Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 14 / Total 29...
  • Page 20: Measurement Steps

    ▲ Note: When signal is incomplete (signal noise is too high, signal quality becomes poorer or signal disappears), the SpO and PR values will become invalid, and the main unit screen will display the component as “--”. Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 15 / Total 29...
  • Page 21: Battery

    2 years. Improper use of batteries may lead to shortened battery life. It is recommended to replace the lithium battery every 2 years or when the charging frequency exceeds 200 times. Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 16 / Total 29...
  • Page 22: Maintenance And Cleaning

    2. Air-dry the device or use a dry, clean cloth to wipe the surface. Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 17 / Total 29...
  • Page 23: Scrapping

    Packages should be scrapped according to applicable national laws or regulations. Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 18 / Total 29...
  • Page 24: Troubleshooting

    1. The probe is not 1. Properly clamp the probe to the displayed is properly finger; instable clamped to the 2. Cut the fingernail. finger; 2. The fingernail is too long. Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 19 / Total 29...
  • Page 25: Product Specifications

    Hardware specification Display screen Multi-purpose multiplex interface One multiplex interface for charging/SpO probe Watchband Environmental Operation Storage specification Temperature (℃) +5~+40 -20~+60 Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 20 / Total 29...
  • Page 26: Technical Description

    2.41 1.51 1.53 2.55 2.34 3.98 Accuracy (Arms) 3.63 2.25 2.88 4.20 4.24 4.81 Below shows the Bland-Altman plot of sample for study on invasive controlled desaturation. Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 21 / Total 29...
  • Page 27 Bland-Altman Plot for SaO -SpO Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 22 / Total 29...
  • Page 28: Network Security

    B. Network Security The WS Series Pulse Oximeter is available with USB port or Bluetooth function. The management software is described as follows:  B.1 The mobile phone management software for the pulse oximeter: The operating environment is a mobile phone installed with Android 8.0 OS or higher compatible version.
  • Page 29: Emc

    Transmission power:<10 dBm Wireless frequency range:2402MHz~2480MHz Hereby, [Hunan Accurate Bio-Medical Technology Co., Ltd.], declares that this [WS20A] is in compliance with the essential requirements and other relevant provisions of RE Directive 2014/53/EU. A copy of the full DoC is attached.
  • Page 30 80 MHz – 2,7 80 % AM at 2 Hz 80 % AM at 2 Hz Note: U is the AC mains voltage prior to application of the test level. Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 25 / Total 29...
  • Page 31 Separation Distance (m) Corresponding to Frequency of Output power of Transmitter Transmitter (W) 150k to 80MHz 80M to 800MHz 800M to 2.7GHz 0.01 0.12 0.04 0.07 0.37 0.12 0.23 Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 26 / Total 29...
  • Page 32 CDMA 850, LTE Band 5 1720 1 700 – GSM 1800; Pulse 1 990 CDMA 1900; modulation 1845 GSM 1900; 217 Hz 1970 DECT; LTE Band 1, 3, Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 27 / Total 29...
  • Page 33 Note 1: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 28 / Total 29...
  • Page 34: Default Factory Settings

    ※ The main unit of oximeter is provided with a two-year warranty period starting from the date of purchase, and the SpO probe has a six-month warranty period. Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 29 / Total 29...
  • Page 35 Copy Right. Hunan Accurate Bio-Medical Technology Co., Ltd Page 29 / Total 35...

This manual is also suitable for:

Ws20a

Table of Contents