1. Test equipment
PM5518 (video signal generator)
VG-848 (VGA and HDMI signal generator)
CA210 (color analyzer)
2 Alignment flow-chart
The alignment flow-chart is shown as fig-1
3 Unit adjustments
Connect all the boards according to wiring diagram, connect with power and observe the display.
Method for entering factory menu: press "INPUT", "2", "5", "8" and "0" in turn to enter factory
menu; press "CH+" and "CH-" to select adjustment items and press "VOL+" and "VOL-" to adjust
value items, press "MENU" continuously to exit.
Method for software upgrading: enter factory menu and select "OPTION", set ISP to 1 or insert
jump wire J201, then you can upgrade the software on line. After upgrade, it needs to set ISP back
to 0 or pull out jump wire J201. After software upgrade finish, please turn off the TV and then turn on,
enter the factory menu and initialize the EEPROM (EEPROM-MEMORAY RECALL).
3.1 Initialization
The items are only for some units which have special demands. They do not need to be adjusted for
normal units.
Enter factory menu, select "OPTION" and "HOTEL OPTION" sub-menu, adjustment of items to see
table1.
Check DDC, HDCP KEY, FLASH and POWER control IC
Factory initialization setup
IF channel AFT voltage of TV and AGC voltage
ADC correction of VGA, YPbPr
White balance adjustment
Performance check
Preset ex-factory