10. Optional adjustments
10.1. Manual ADC Calibration
■ Enter 'EZ ADJUST' mode by pressing 'ADJ' key.
■ Enter Internal ADC calibration mode by pressing '' or 'OK'
key at '7. ADC Calibration'
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Country Group
6. Area Option
7. ADC Calibration
8. White Balance
9. 10 Point WB
10. Test Pattern
11. EDID D/L
12. Sub B/C
13. Touch Sensitivity Setting
14. Ext. Input Adjust
► Caution : Using 'P-ONLY' key of the Factory Service remote
control when turns TV on.
10.2. Manual White balance Adjustment
10.2.1. Adjustment condition and cautionary items
(1) Lighting condition in surrounding area surrounding lighting
should be lower 10 lux. Try to isolate adj. area into dark
surrounding.
(2) Probe location: Color Analyzer (CA-210) probe should be
within 10cm and perpendicular of the module surface.
(80°~ 100°)
(3) Aging time
1) After Aging Start, Keep the Power ON status during 5
Minutes.
2) In case of LCD, Back-light on should be checked using
no signal or Full-white pattern.
10.2.2. Equipment
(1) Color Analyzer: CA-210 (NCG: CH 9 / WCG: CH12 / LED:
CH14)
(2) Adj. Computer(During auto adj., RS-232C protocol is needed)
(3) Adjust Remot control
(4) Video Signal Generator MSPG-925F 720p/216-Gray
(Model: 217, Pattern: 78)
10.2.3. Adjustment
(1) Set TV in Adj. mode using POWER ON.
(2) Zero Calibrate the probe of Color Analyzer, then place it on
the center of LCD module within 10cm of the surface.
(3) Press ADJ key → EZ adjust using adj. R/C → 6. White-
Balance then press the cursor to the right (Key►). When
Key(►) is pressed 216 Gray internal pattern will be
displayed.
(4) One of R Gain / G Gain / B Gain should be fixed at 192,
and the rest will be lowered to meet the desired value.
(5) Adj. is performed in COOL, MEDIUM, WARM 3 modes of
color temperature.
■ If internal pattern is not available, use RF input. In EZ Adj.
menu 6.White Balance, you can select one of 2 Test-pattern:
ON, OFF. Default is inner(ON). By selecting OFF, you can
adjust using RF signal in 216 Gray pattern.
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
ADC Calibration
NG
ADC Comp 480i
NG
ADC Comp 1080p
NG
ADC RGB
Start
Reset
- 11 -
LGE Internal Use Only