  • Page 1 FC-630 TECHNICAL/USER MANUAL AND SERVICE BOOK...
  • Page 3 USER MANUAL INDEX Main features Unpacking Introduction Types of dispenser treatments Advance warnings Equipment operation Installation Carbon filter rinsing System tightness check, stop and start. (RO) Cleaning and maintenance Sanitation procedure User interface Troubleshooting TECHNICAL MANUAL INDEX Technical characteristics Identification of management and control components How to extract water from the dispenser User interface How to access the filters...
  • Page 4 Data sheet...
  • Page 5: Main Characteristics

    TECHNICAL SHEET FC-630 0. MAIN CHARACTERISTICS DIRECT */**/*** FILTER ** ACCESS EQUIPMENT WITH EASE OF ACCESS FILTRATION SYSTEM AND MAINTENANCE COLUMBIA FILTERS */**/*** ULTRAFILTRATION *** EQUIPMENT WITH ULTRAFILTRATION EXCLUSIVE FILTERS SYSTEM MAXIMUM SAFETY AND HYGIENE COLUMBIA* MEMBRANE COLD */**/*** MAXIMUM HYGIENE...
  • Page 6: Security Instructions

    SECURITY INSTRUCTIONS If the appliance is not installed Below are safety warnings and correctly, it can lead to dange- instructions to prevent injury to rous circumstances. Make sure the user and to prevent material that the following conditions are damage to the user’s environ- met: ment.
  • Page 7 The mains cable must not be must not be bent, crushed, mo- bent, crushed or modified, nor dified or cut. must it come into contact with The use of tubes distributed sources of heat. by other brands to connect the The use of extension cords or water supply could cause ma- power strips could cause a...
  • Page 8 1. UNPACKING 3. TYPES OF TREATMENTS OF COLUMBIA AQUA DISPENSERS It is important that before installation and start-up, Columbia dispensers are available, depending on the check the box and condition of the equipment, in or- model, with different types of water treatment: filtra- der to guarantee that it has not been damaged during tion, ultrafiltration and reverse osmosis.
  • Page 9: Advertencias Previas

    If you have any questions about the installation, use or maintenance of this equipment, contact the • COLUMBIA equipment should not be installed lying technical assistance service (SAT) of your distributor. down or tilted. They must be placed on a flat surface for correct and safe operation.
  • Page 10: Equipment Operation

    6. INSTALLATION Attention: Special attention should be paid to the cleaning and hygiene of the front The installation of your Columbia Dispenser must be dispensers, on a regular basis and especially carried out by personnel qualified enough for it. Check when carrying out periodic maintenance and with the dealer if in doubt.
  • Page 11: Cleaning And Maintenance

    Attention: Some of the installation accessories and could cause them to malfunction and become may vary depending on the model and region in dirty and/or reduction of the useful life of certain which the equipment is distributed. components. Use the appropriate tools and sealants to ensure the On RO models;...
  • Page 12: Sanitization Procedure

    Attention: In order to guarantee the quality of Attention: In case of detecting that the water the water supplied by your equipment, periodic dispensed does not comply with current national maintenance must be carried out. legislation, close the input key of the equipment, empty it through the tap, disconnect it electrically and Recommended maintenance contact your technical service.
  • Page 13 CLOSED • Keep the inlet valve closed (6) and empty the accumu- OPEN CERRADA ABIERTA lation tank through the front dispensers (see chapter “how to extract water”) • Sanitization must be carried out with the new pre- and post-filters installed and properly rinsed beforehand, correctly removing carbon dust from them.
  • Page 14: Solution Of Problems

    12. . SOLUTION OF PROBLEMS THE TANK IS NOT FILLED AT ALL Problem Cause Solution 1. No water enters the dispenser The inlet valve is closed Open the inlet valve The dispenser is unplugged Plug the dispenser into the mains The switch is OFF Position the switch to ON No water supply...
  • Page 15 WATER DOES NOT STOP COMING OUT OF THE DRAIN 9. The dispenser never stops The level switch does not respond Cambiar el interruptor de nivel. pouring water down the drain to the full tank command (Check with a voltmeter) The inlet solenoid valve has stuck Cambie la electroválvula de INLET.
  • Page 16: Technical Characteristics

    1. TECHNICAL CHARACTERISTICS APPLICATION ROP Model (Reverse Osmosis) F Model (Filtration) UF Model (Ultrafiltration) Improvement of the characteristics of drinking water (that complies with the requirements of the European Direc- tive on water for human consumption 98/83 or its national transpositions in the different member states of the European Community).
  • Page 17 TECHNICAL DATA 1 Sediment pre-filter 1 Sediment pre-filter 1 Sediment pre-filter Treatment 2 GAC Prefilters 1 Carbon Prefilter 1 Carbon Prefilters 1 BLOCK pre-filter 1 Ultrafiltration prefilter 1 RO 50 GPD membrane 1 Carbon postfilter 1 Carbon Postfilter (A x B x C) 480 x 285 x 420 mm Dimensions: 16 kg Weight:...
  • Page 18 UF MODEL HYDRAULIC DIAGRAM VALVE FLOAT COLD WATER TANK TANK EMPTY HOT WATER INLET HYDRAULIC DIAGRAM MODEL F VALVE FLOAT COLD WATER TANK TANK EMPTY HOT WATER INLET Data sheet...
  • Page 19 ROP MODEL ELECTRICAL DIAGRAM SWITCH HEATER SYSTEM SWITCH REFRIGERATION SYSTEM CONTROL TEMPERATURE II CONTROL TEMPERATURE II F/UF ELECTRICAL DIAGRAM SWITCH HEATER SYSTEM SWITCH REFRIGERATION SYSTEM CONTROL TEMPERATURE II CONTROL TEMPERATURE II...
  • Page 20 ESQUEMA DE CONEXIONADO HIDRÁULICO MODELO ROP ENTRANCE / INLET DRAIN ESQUEMA DE CONEXIONADO HIDRÁULICO F/UF ENTRANCE / INLET Data sheet...
  • Page 21 2. IDENTIFICATION OF THE MANAGEMENT AND CONTROL COMPONENTS 1. Status indicators. 8. Cold system switch. Red light on the left indicates that the water heating system is Activate the switch if you want the dispenser to have cold heating. water. If you keep it in the OFF position, you can extract Yellow light in the center indicates that the ambient water from the cold tap.
  • Page 22: User Maintenance

    3. HOW TO DRAW WATER FROM THE DISPENSER 5. HOW TO ACCESS THE FILTERS To draw cold water: Press the lever on the right side Grasp the lower front cover with both hands and pull it of the dispenser with the glass to let the cold water away from the unit while pulling it slightly downward.
  • Page 23: Warranty

    7. WARRANTY This equipment has a warranty period as established in the legislation in force. - The warranty includes the repair and replacement of defective parts by personnel authorized by the distributor or by the official technical assistance service (T.A.S.) at the place of installation or at its workshops. Labor and shipping costs that may be incurred are included in the warranty.
  • Page 24 INSTALLATION REGISTER SHEET NOTES TO THE TECHNICIAN/INSTALLER: read this manual carefully. If in doubt, contact your dealer’s Technical Support Service (T.A.S.). The data marked with the symbol * must be filled in by the technician/installer and transcribed by him/herself to the WARRANTY page. This sheet must be kept by the installer and may be requested by the distributor in order to improve after-sales service and customer service.
  • Page 25: Maintenance & Service

    9. MAINTENANCE SERVICE DATE TYPE OF SERVICE NAME, SIGNATURE AND STAMP OF TECHNICIAN START-UP COMPLETE MAINTENANCE TECHNICIAN PREPARATION STAMP ORDINARY SANITIZATION EXTRAORDINARY OTHERS WARRANTY COMPLETE MAINTENANCE TECHNICIAN PREPARATION STAMP ORDINARY SANITIZATION EXTRAORDINARY OTHERS WARRANTY COMPLETE MAINTENANCE TECHNICIAN PREPARATION STAMP ORDINARY SANITIZATION EXTRAORDINARY OTHERS...
  • Page 26 9. MAINTENANCE SERVICE DATE TYPE OF SERVICE NAME, SIGNATURE AND STAMP OF TECHNICIAN START-UP COMPLETE MAINTENANCE TECHNICIAN PREPARATION STAMP ORDINARY SANITIZATION EXTRAORDINARY OTHERS WARRANTY COMPLETE MAINTENANCE TECHNICIAN PREPARATION STAMP ORDINARY SANITIZATION EXTRAORDINARY OTHERS WARRANTY COMPLETE MAINTENANCE TECHNICIAN PREPARATION STAMP ORDINARY SANITIZATION EXTRAORDINARY OTHERS...
  • Page 27 10. NOTES...