80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
AVERAGE EFFICIENCY :
80 PLUS COMPLIANT:
Ecos ID #
932
THERMALTAKE
Manufacturer
W0132 Toughpower 1000 A
Model Number
Serial Number
NA
Year
2008
Type
EPS12V
7/11/2008
Test Date
Rated Specifications
Input Voltage
Input Current
Input Frequency
Rated Output Power
Note: All measurements were taken with input voltage at 115 V nominal and 60 Hz.
I
I
(%)
Load
PF
RMS
THD
(%)
A
2.15
0.99
4.3%
20%
5.10
1.00
3.3%
50%
10.36
1.00
2.7%
100%
Input and Output Power
1400
1200
1000
800
600
400
200
0
20%
Loading (% of Rated Output Power)
Value
100-240 Volts
13
47-63
1000
Fraction
Input
of Load
Watts
12V (cumulative of 12V1, 12V2, etc.)
244
Light
585
Typical
Full
1190
Input Watts
Output Watts
50%
100%
These tests were conducted as a part of the 80 PLUS program. 80 PLUS is
a computer buy-down program to promote high-efficiency power supplies
(greater than 80% efficiency in the active mode) in desktop computers and
desktop-derived servers.
Tested by Electric Power Research Institute, Knoxville, TN.
86.01%
84.10%
YES
Units
Amps
Hz
Watts
DC Terminal Voltage (V)/ DC Load Current (A)
12.2/13
12.1/32.6
12/65.1
90%
80%
70%
60%
50%
40%
30%
Input Current and Voltage Waveforms
200
150
100
50
0
0
0.003
0.006
0.009
-50
-100
-150
-200
Time (s)
Voltage
Input AC Current Waveform (ITHD = 3.28%, 50% Load)
-12V
3.3V
5V*
12.1/0.1
3.3/4.8
5/4.7
12.1/0.3
3.2/11.8
4.9/11.9
4.9/1.4
12.2/0.6
3.1/23.5
4.8/23.7
4.6/2.8
Efficiency of the Power Supply
0%
25%
50%
Loading (% of Rated Output Power)
15
10
5
0
0.012
0.015
-5
-10
-15
Current
Output
Efficiency
5VSB
Watts
%
5/0.6
203
83.28%
503
86.01%
987
83.01%
Efficiency %
75%
100%
125%
Need help?
Do you have a question about the W0132 and is the answer not in the manual?
Questions and answers