Installing your Freestanding Cooker

Electrical connection

IMPORTANT: Electrical connections must be carried out by a suitably qualified
person and in accordance with all relevant local building and installation regulations.
Fitting on a Power Supply Cable
Connecting appropriate power supply terminal board/ connector block:
Using a screwdriver, prize open tabs of the Terminal board cover.
Remove the wire clamp screw.
Fasten the wires beneath the corresponding screw heads, using brass 'bridge'
for single phase supply.
Fasten cable clamp and close the cover of the terminal board.
The ac power supply should be 220-240 V, 50/60 Hz. For electric cookers, the
minimum 32A fuse, or at least 32A distribution circuit breaker.
Warning: Connect the power cord in accordance with the instructions listed in the
table below.
Wire cross-sectional area(mm2)
Connection mode
1N~
Connecting the supply cable to the mains
Install an approved circuit breaker with a contact opening of 4 mm , between
the appliance and the mains fuse box .The circuit breaker should be sized
according to the load and should comply with current regulations (the earth wire
should not be interrupted by the circuit breaker).
L
4mm
4mm
2
12
N
E
4mm
2
2
2