INSTALLATION, OPERATION & MAINTENANCE MANUAL WHD-BSN
®
Model WHD-BSN
LIGATURE RESISTANT
CORTERRA BASIN ADA
COMPLIANT
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:
Technical Assistance E-mail: Fieldservice@acorneng.com
Important: Some options may slightly alter installation. To ensure proper installation review the manual thoroughly and
verify rough-ins before beginning any work. File this manual with the owner or maintenance personnel upon completion of
installation.
Industry standard wall backing, for wall hung fixtures, is required. Installer provided wall anchors and wall anchoring
hardware must be appropriate for wall construction.
ANSI, UFAS or ADA compliance is subject to the interpretation and requirements of the local code authority and is the
responsibility of the installer for verification.
Single Temp Valve Assembly: Recommended working water pressure is 30 psi (2.07 bars) minimum to 100 psi (6.89 bars)
maximum. Maximum temperature is 130°F (54.4°C). Maximum outlet temperature recommended is 105°F (40.6°C).
Valve assembly must be drained prior to being subjected to freezing temperatures. A checkstop is provided with this valve
assembly.
T/P Mixing Valve Assembly: Recommended working water pressure is 30 psi (2.07 bars) minimum to 100 psi (6.89 bars)
maximum. Maximum hot water temperature is 180°F (82°C). Temperature adjustment range is 85-115°F (29-46°C).
Minimum hot water supply temperature must be 5°F (3°C) above desired set temperature. Valve assembly must be
drained prior to being subjected to freezing temperatures. The valve assembly has checks integral to the inlets however,
angle stops are to be provided by the installer.
Prior to installation, supply lines must be flushed of all foreign material such as pipe dope, chips, or solder. Debris or
foreign material in water supply may damage valve.
Teflon tape is recommended on all threaded waste and supply connections to reduce the possibility of leaks.
Provide 110-120VAC/60Hz/3A (MAX) electrical receptacle for factory supplied 120VAC/9VDC, 100mA plug-in
transformer.
NOTE: Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth grounded per N.E.C. (National
Electrical Code).
Please refer to the Link or QR code provided.
For Cleaning & Care Guide:
https://www.whitehallmfg.com/uploads/fileLibrary/9900-008-W01.pdf
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
6900-220-001 Revised: 10/17/2023 B
TM
1.800.743.8259
WHD-BSN-WH3375-SO
(Photo shows optional accessories)

Advertisement

loading

Summary of Contents for Whitehall WHD-BSN

  • Page 1 NOTE: Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth grounded per N.E.C. (National Electrical Code). Please refer to the Link or QR code provided. For Cleaning & Care Guide: https://www.whitehallmfg.com/uploads/fileLibrary/9900-008-W01.pdf WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A 6900-220-001 Revised: 10/17/2023 B...
  • Page 2: Technical Dimensions

    DIMENSIONS SHOWN ARE FOR RECOMMENDED ADULT HEIGHT. ADJUST VERTICAL DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL, STATE, & LOCAL CODES. STOP VALVE NOT PROVIDED. WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 • Web: www.whitehallmfg.com...
  • Page 3 1/2" NPS Hot & Cold Supplies, Rough-In as required (Angle Stops by others). When required for Sensor Faucet 120VAC, 60Hz, 3A (Max) GFCI Protected Electrical Receptacle. WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 • Web: www.whitehallmfg.com...
  • Page 4 Lockwasher (Provided). DECK DECK DETAIL B MOUNTING ASSEMBLY CHANNEL DETAIL A 1/4” SCREW, WASHER, AND LOCKWASHER (PROVIDED) FRAME FRAME MOUNTING CHANNEL ASSEMBLY WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 • Web: www.whitehallmfg.com...
  • Page 5: Top View

    [77] 2" [51] Assemble waste piping using teflon tape on all threaded connections and make up waste connections to 1-1/2" P-trap. WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 • Web: www.whitehallmfg.com...
  • Page 6: Valve Installation

    1/2" NPS flex hoses to valve. For -ST Single Temperature valves, flush supply line. Connect installer provided 1/2" NPS flex hose to valve. WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 • Web: www.whitehallmfg.com...
  • Page 7 TEMPERATURE temperature. STEM 4) Tighten locknut to prevent accidental or WARMER unauthorized temperature adjustment. 5) Re-check outlet temperature. WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 • Web: www.whitehallmfg.com...