Condensate Drain - Beko DRYPOINT RAX 200 NA 3PH UL Instructions For Installation And Operation Manual

Compressed air refrigeration dryer
Table of Contents

Advertisement

8.8

Condensate drain

Danger!
Compressed air and condensate under pressure!
The condensate is discharged at system pressure.
The drain pipe needs to be secured.
Never direct the condensate drain pipe at persons.
The dryer is delivered with an already integrated electronically level-controlled BEKOMAT condensate drain. Connect
the condensate drain with a collection system or container by properly screwing it on.
Do not connect the drain with pressurised plants.
Do not discharge the condensate into the environment.
The condensate accumulating in the dryer contains oil particles which were released into the air by the
compressor.
Dispose of the condensate in accordance with the local provisions.
It is advisable to install a water-oil separator, to which the total amount of condensate from the
compressors, dryers, tanks, filters etc. is supplied.
We recommend ÖWAMAT oil-water separators for dispersed compressor condensate and BEKOSPLIT
emulsion-splitting plants for emulsified condensate.
DRYPOINT® RAX 200-500 NA 3PH UL
Installation
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drypoint rax 250 na 3ph ulDrypoint rax 300 na 3ph ulDrypoint rax 350 na 3ph ulDrypoint rax 400 na 3ph ulDrypoint rax 500 na 3ph ul