General Safety Information - Pentair HYPRO HM1C Product Bulletin

Table of Contents

Advertisement

Notes are used to notify of installation, operation, or
maintenance information that is important but not
safety related.
Caution is used to indicate the presence of a hazard,
which will or may cause minor injury or property
damage if the notice is ignored.
Warning denotes that a potential hazard exists and
indicates procedures that must be followed exactly to
either eliminate or reduce the hazard, and to avoid
serious personal injury, or prevent future safety
problems with the product.
Danger is used to indicate the presence of a hazard
that will result in severe personal injury, death, or
property damage if the notice is ignored.
Do not pump flammable or explosive fluids such as
gasoline, fuel oil, kerosene, etc. Do not use in explosive
atmospheres. The pump should be used only with
liquids compatible with the pump component materials.
Failure to follow this notice may result in severe
personal injury and/or property damage and will void
the product warranty.
1. Always drain and flush pump before servicing or
disassembling for any reason.
2. Always drain and flush pumps prior to returning
unit for repair.
3. Never store pumps containing hazardous
chemicals.
4. Before returning pump for service/repair, drain out
all liquids and flush unit with neutralizing liquid.
Then, drain the pump. Attach tag or include written
notice certifying that this has been done. It is illegal
to ship or transport any hazardous chemicals
without United States Environmental Protection
Agency Licensing.

General Safety Information

1. Do not pump at pressures higher than the
2. Maximum liquid temperature is 140
3. Disconnect power before servicing.
4. Release all pressure within the system before
5. Drain all liquids from the system before servicing
6. Secure the outlet lines before starting the pump. An
7. Check hose for weak or worn condition before each
8. Periodically inspect the pump and the system
9. Use only pipe, hose and fittings rated for the
10. Do not use these pumps for pumping water or other
Hazardous Substance Alert
Never use your hand to check the condition of
hydraulic lines or hoses. If hydraulic fluid penetrates
the skin, get medical help immediately. Failure to get
proper medical help may result in loss of limb or life.
The safest way to check hydraulic lines or hoses is by
holding a piece of cardboard next to the hydraulic line
or hose.
The sound pressure level of the pump is 80dBA.
Observe all safety precautions when operating the
pump within close proximity for extended periods of
time by wearing hearing protectors. Extended exposure
to elevated sound levels will result in permanent loss of
hearing acuteness, tinnitus, tiredness, stress, and other
effects such as loss of balance and awareness.
-2-
maximum recommended pressure.
9300 centrifugal pumps.
servicing any component.
any component. Flush with water.
unsecured line may whip, causing personal injury
and/or property damage.
use. Make certain that all connections are tightly
secured.
components. Perform routine maintenance as
required (See Repair Instructions).
maximum psi rating of the pump.
liquids for human or animal consumption.
F for Series
o