The illustration below includes cutout dimensions and minimum spacing requirements. The illustration is for reference. The design
of your cabinet layout can be personalized, but the dimensions for the cutouts and minimum spacing must be followed.
Counter or support surfaces must be level.
The installation of this side burner must conform with local codes or, in the absence of local codes, with either the National Fuel
Gas Code, ANSI Z223.1/NPFA 54, Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling
Code, B149.2.
NOTE: The outdoor side buner drops into the enclosure opening and is supported by its side flanges. Do not use a bottom support.
Built-in Outdoor Side Burner Enclosure Ventilation for LP Gas
Any enclosure is to be ventilated by openings at both the top
and lower levels of the enclosure. The following information is
the minimum for proper ventilation of your island construction.
There should be a minimum of 1 7/8" (4.4 cm) of clearance
from the bottom of the main burner bowl assembly island
for proper ventilation.
NOTE: There should be no solid surface underneath the
firebox portion of the side burner.
A minimum of 3" (7.6 cm) is required between the back of
the side burner and any noncombustible materials. A
minimum of 36" (92 cm) is required between the back of
the side burner and any combustible material.

Cabinet Cutout Dimensions

13
The island must be vented in one of the 2 following ways:
A 90°or a 180°ventilation in the island to ensure that air
flows through the island at either 90°or 180°.
Any enclosure for built-in installation is to have at least
one ventilation opening on an exposed exterior side
located within 2½" (6.0 cm) of the top and is to be a
2
minimum of 20 in.
(129.0 cm
within 1½" (3.0 cm) of the bottom of the enclosure, and the
bottom opening is to be a minimum of 10 in.
All vent openings are to be unobstructed. Every opening is
to be a minimum of 1/8" (0.32 cm) wide.
2
). One ventilation opening
2
2
(64.5 cm
).