JVC RM-C326 Service Manual page 29

Basic chassis gj
Table of Contents

Advertisement

Measuring
Item
instrument
SUB TINT
Signal
adjustment
gener ator
Remote
control unit
Signal
gener ator
Oscilloscope
Remote
control unit
Y
Cy
W
Test point
Ad justment part
S04:TINT
TP-B
S04:TINT
TP-E(# # # # )
[CRT
SOCKET
PWB]
G
R
(B)
(
)
B
0V
(
)
Mg
[ Method of adjustment without measuring instr ument ]
1. Receive the broadcast.
2. Enter the SERVICE MENU.
3. Select S04:TINT of the V/C(S) mode.
4. Set the initial setting value of the S04:TINT with the
FUNCTION
/
5. If the tint is not the bes t with the initial setting value, make fine
adjustment of the S04:TINT until you get the optimum tint.
No .
Setting item
S04
TINT
[ Method of adjustment using measuring instrum ent ]
1.
Input the full field c olor bar signal (75% white).
2.
Enter the SERVICE MENU.
3.
Set the RFAFC to OFF.
4.
Select S04:TINT of the V/C(S) mode.
5.
Set the initial setting value of the S04:TINT with the
FUNCTION
/
6.
Connect the osc illosc ope between TP-B and TP-E.
7.
Adjust TINT and bring the value of
voltage shown in the table bellow.
8.
Reset the RFAFC setting pos ition from OFF to ON.
W-Mg
Models
AV-27F703
/S
AV-27F713
/S
AV-27F803
/S
No.52005
Description
key.
Variable
Initial setting
range
value
68
0~127
key.
(B)
in the illustration to the
[B]Voltage
+26V
AV-27F703
AV-27F713
AV-27F803
29