The date of change appears from the front and back pages. Note • All rights belong to SKOV A/S. No part of this manual may be reproduced in any manner whatsoever without the expressed written permission of SKOV A/S in each case.
It is designed for touch-free operation, using infrared light. It reduces the risk of eggshell fractures and contami- nation and ensures an unhampered flow of eggs on the conveyor belt. DOL 192 egg counter is available in 5 different scan widths (12, 20, 40, 50, and 80 cm) to suit different types of conveyors.
130387 DOL 192 egg counter, 80 cm Scan width 792 mm Cable length 2 m The DOL 192 is suitable for counting eggs on conveyor belts that collect eggs from multiple longitudinal conveyor belts. Used for counting eggs with an egg diameter of 36-55 mm.
DOL 192 Egg Counter 2.1 Accessories 135752 Power supply 24V, 2.1A in box Extra power supply. Voltage 90 – 264 V Frequency 47-63 Hz Power 160 VA/ 80 W Current 0.7 A Output Voltage 24 V +/- 10 % Current 2.1 A 136470 BlueControl extension box 10RL Extension box with 1 pcs.
Page 7
DOL 192 Egg Counter 130183 DOL 100 digital 8l box 130184 DOL 100 digital 16l box 130191 DOL 100 digital 24l box 130192 DOL 100 digital 32l box External I/O box for connection of water meter, egg counter, or capacitive sensor.
DOL 192 Egg Counter 3 Mounting guide 3.1 Recommended tools A list of tools recommended for the installation of your egg counter can be seen below. Topic Description Cordless drill Screwdriver bits Drill kit Utility knife Multimeter Tape measure Side cutter...
DOL 192 Egg Counter 3.2 Mounting the egg counter The egg counter is mounted on the bracket directly over the conveyor belt. For the egg counter to count optimally, place it where the eggs cannot roll or move sideways. Eggs that move around may be counted more than once.
Page 10
Adjust the height of the egg counter when the size of the egg changes. Adjust the egg counter to fit the conveyor belt. Tighten all U- bolts. Install the DOL 192 box as close to the egg counter as pos- sible. Do not extend the supplied 2-meter cable. Technical User Guide...
The installation of a power supply isolator is required for each motor and power supply to facilitate voltage-free work on the electrical equipment. The power supply isolator is not included. 4.1 Connecting the egg counter to the DOL 192 box 4.1.1 Cable diagram egg counter...
– ON: When 2 DOL 192 egg counters are connected to a DOL 192 box 24V. Select whether the DOL 192 box uses one pulse per egg or one pulse per five eggs (a maximum of 5 pulses per second).
DOL 192 Egg Counter 4.4 Choice of egg counter in controller | Installation | Manual installation | Production | Installation | Egg counting and select Automatic | Installation | Manual installation | Production | Installation | Egg settings | Egg counters installed Enter the number of egg counter to be installed.
DOL 192 Egg Counter 4.5 Clock setting DOL 192 box w/display The clock must be set to the current time. Use the up/down arrows to navigate to the clock display. Time: • Press arrow to the right. Adjust hours using the up/down arrow.
DOL 192 Egg Counter 5 General information about circuit diagrams Symbols are in accordance with the IEC/EN 60617 standard. The classification of the symbols ("letter codes") on the symbols is in accordance with the IEC/EN 81346-2 stan- dard. Reference designations are in accordance with IEC/EN 81346-1:2001 structuring principles and reference des- ignations.
Supply DOL 192 Egg Counter DOL 192 box 24 V f/2 egg counters Standby 6.2 Circuit diagram DOL 192 box 24 V 1 egg counter Example of terminal number For correct connection see the setup menu Show connections in the controller...
DOL 192 Egg Counter 7 User Guide 7.1 Operating DOL 192 box w/display Use the up/down arrows to navigate through the various views. The number of eggs today: The number of eggs counted per hour (in this example, 90 eggs per hour - '90/h').
DOL 192 Egg Counter 8 Maintenance instructions 8.1 Cleaning The egg counter is maintenance-free but should be kept free of dirt and filth. Clean the product with a cloth that has been wrung out almost dry in water and avoid using: •...
DOL 192 box. Flashes red (8 Hz) Selected incorrect number of egg counters. 9.2 Error messages DOL 192 box w/display The DOL 192 box w/display checks the counter operations. The following error messages may occur. Alarm Type Cause Possible solution...