Note: All contents in this chapter are related to safety, users must comply with it. All contents in this chapter are only for the correct use of this product.
![]() | |||||
![]() | Avoid installing under direct sunlight and outdoor places | ![]() | Do not expose to an environment below 0 ºC | ![]() | Do not store flammable items near the machine |
![]() | When the machine breaks down, please cut off the water and power supply quickly | ![]() | Keep out of reach of children Please do not let children operate the machine | ||
![]() | Do not disassemble the machine by yourself as to prevent water leakage and damage to the machine | ![]() | Please make sure the temperature of water source is 5-38 ºC | ||
![]() | When the machine will be inactive for more than 24 hours, please shut down its water source and turn off its power supply | ![]() | In order to run the machine smoothly, please use accessories and filter cartridges from Bluevua |
Open the packaging and take out the entire machine, as well as all the accessories. Confirm them in accordance with the list to ensure that nothing is missing or damaged during the shipping. If there is any part broken or cracked, please stop the installation and contact Bluevua Support Team instead. To ensure a smooth installation, please watch the installation video from our website: www.bluevua.com
Tel 1-888-637-0009 Mon-Fri 9:00 AM-5:00 PM CST
Email: support@bluevua.com
Product Model | RO500X6-Bluevua |
Product Size (L*W*H) | L425*W150*H417mm |
Feed Water Pressure | 0.15~0.4 MPa |
Feed Water Temperature | 41~100ºF / 5~38ºC |
Feed Water Requirement | Tap Water |
Pure Water Rate | 1.3L Per Minute / 500 Gallon Per Day |
Power Specifications | Input 100~240V AC |
Output 24V DC; 3.0A |
Note: The pure water rate is affected by water pressure and water temperature. The feed water is measured under 0.2 MPa water pressure and 25ºC water temperature. When water pressure and water temperature fluctuate, the water rate also fluctuates.
The accessories are installed and connected as shown in the following (Figure 2). For a more efficient installation, please check and be familiar with the corresponding location (Figure 1), and remember to press the unlocking ring (Figure 12) to remove the trumpet-shaped cap from the port before the installation.
LEGEND
Step 1: | A to B | RO Feed Water Adapter to Feed Water Port |
Step 2: | C to D | Pure Water Port to RO Faucet |
Step 3: | E to F | Waste Water Port to Drain Pipe |
Step 4: | G to H | Water Leakage Protector to Water Leakage Protector Port |
Step 5: | I to J | Power Outlet to Power Port |
Note 2: For 4 and 5, If the cold water pipe is 3/8" instead of 1/2'', please use the attached 3/8" converter (Figure 3).
Indicator | Operating Status | Display |
Power-On | When power is on, the buzzer plays power-on sound, all button lights and digital function menus are on. The system will do self-check. If there is no alarm, the system will switch to auto-flushing mode after 3 seconds. | The indicator of the PCP/RO/CF filter is always on. It lights up when it is in the state of auto-flushing and pure water-making. |
![]() FLUSH | ||
![]() WORK | Turn on the RO faucet, the machine automatically starts water production. Turn off the RO water faucet, the machine stops producing water. | The indicator flashes during water-making process, and turns off when the process is done. |
![]() PCP ![]() RO ![]() CF | When one or more filters expire, the alarm buzzer rings rapidly as a routine filter replacement reminder. The alarm repeats on every attempt of pure water-making. After 360 hours (15 days) of alarm, the system will turn off inlet solenoid valve and booster pump. The indicators must be reset to restart the lifetime reminder after the filter replacement. | The indicators remain white under normal status. When the filter expires, the indicator flashes red until the replacement and reset process are completed. |
![]() SELECT ![]() RESET | After replacing the filter(s), long-press the Select indicator for 3 seconds to enter filter selecting mode, then press the indicator to switch between different filters. For a selected filter, long press the Reset indicator for 5 seconds to complete the reset process. | The indicators remain on at all time, and remain off during standby mode. |
PCP Polypropylene Activated Carbon Filter | 12 Months |
RO Reverse Osmosis Membrane Filter | 24 Months |
CF Carbon Filter | 12 Months |
Note:
The system automatically enters flushing mode under the circumstances below:
To detach the PE tube from the machine, use the adjustable wrench to press the circle unlocking ring of the quick-connect fitting then pull out the tube.
Q Why the system does not function?
A1 Power-saving mode: Reset the power or touch the button several times quickly to leave the mode.
A2 Power failure: Check if there is power outage. Check if the power adapter is properly connected to the machine and power outlet. Or simply disconnect the system and try another power outlet.
A3 Power adapter failure: Replace the power adapter. If you are unsure about the model of adapter, please contact our Customer Service for further assistance
A4 Leakage alarm activated: The system automatically shuts down when the leakage protector detects a leak. Check and make sure all tube joints and filters are tightened, and check if the protector is accidently triggered by moisture/liquid near the machine. Either way, unplug the water leakage protector and clean up the water. After cleaning, press the RESET button to start again.
Q Why there is no water dispensing from the RO faucet or the water output becomes weaker?
A1 Excessive bending of water tube: Check and straighten out the tube.
A2 RO feed water adapter is being turned off: Check and make sure the RO feed water adapter switch is being turned on.
A3 Water outage occurred: Check if there are any water outage in the area. If yes, please wait for the local water supply to be fixed.
A4 Filters clogged: Check filters to see if they are properly inserted. Make sure all the filters are replaced and have not expired yet.
A5 Feed water pressure lower than rated value: Check and make sure the tubing is properly connected and no leakage on the pipe(s).
A6 Temperature of feed water is low: Check and make sure the system runs at water temperature between 41-100°F.
Q Why the pure water looks dirty?
A Activated carbon particles: It is normal that the pure water turns black with activated carbon particles in the new CTO filter. Do not drink until the 30 minutes of flushing process is completed.
Q Why the pure water smells abnormal?
A1 Filter protective liquid remained: The brand new filter is covered with protective liquid that needs to be washed off. Turn on the RO faucet for 30 minutes to flush out the liquid after replacing filters.
A2 Expired filters remain unchanged for a long period: Replace the filters A3 The machine has remained unused for a long period: Restart the machine and turn on the RO faucet to run for 10 minutes. If the smell remains, please replace the filters.
Q Why the filters are clogged shortly after filter replacement?
A Actual lifetime and condition of a filter may vary due to different quality of water supply or different water usage. Poor water quality and high operating frequency might lead to the shorter lifetime.
Q Why the machine makes loud noise during operation?
A1 The vibration generated by the pump: Move the machine away from the side wall. Do not place the machine against the side wall or on the uneven ground.
A2 Unstable feed water pressure: Check and confirm the water pressure is between 21.7-58 PSI / 0.15-0.4 MPa.
A3 Abnormal power voltage: Contact our support team for assistance. Do not attempt to repair as there may be electrical leakage.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.