When replacing a thermocouple ensure replacement is same type as one removed by ensuring part number/wire colors match. If stagger does not match use stagger adapter P/N 42523. In a new installation, make sure the location on a single probe (thermocouple) Exhaust Gas Temperature system is in the exhaust pipe of the cylinder that is leanest during full throttle. Particularly in carbureted engines, the leanest cylinder can change when throttle, altitude, carburetor heat, and/or ambient air temperature changes. The leanest cylinder is the one that reaches peak first when leaning from full rich, which is sometimes the cylinder with the highest EGT. Additional information on mixture management can be found in Alcor's publication EGT Combustion Analysis in a Nutshell and Lycoming Service Bulletin 1094D, and Continental Service Bulletin M89-18. The probe should be located a minimum of 2 inches from the cylinder exhaust port flange (5 inches for highly supercharged engines) in an area free from weld beads or pipe irregularities. If the pipe has a longitudinal weld bead, orient the clamp so that the bead does not interfere with flush fit of shoulder of flange at base of probe tip (gas seal). Determine the location that will allow probe and wire to be free from interference with spark plugs, baffling, cowling, exhaust and other components. For screw-in type Alcor probes use weld boss, P/N 28113 located the same distance as clamp style probes or 3-5 inches from the turbocharger inlet in Turbine Inlet Temperature sensing applications. All work to be done in accordance with FAA, Advisory Circular 43.13-1B or later revision.
Follow steps 5 and 6 above to complete installation.
NOTE: This is typically the recommended depth of insertion for all Alcor thermocouples.
On a new single probe installation, which cylinder do I install the thermocouple on?
This would be the cylinder where the temperature peaks first while leaning. Not all engines, even of the same make and model, will peak the same due to differences in internal airflow characteristics, carburetion, injection, etc. A worst case scenario would be installing the probe on the richest running cylinder (peaks last) where lean misfire would be reached before peak while leaning.
I installed a new probe and the meter is still dead or went dead again after being in operation for awhile?
First make sure that the correct type of probe was installed by verifying color code matches lead and meter (Type K, Red/Yellow, or Type E, Red/Brown). If that checks all right then disconnect the lead from the meter and measure the loop resistance of the lead and probe and compare it with the value marked on the meter label. If the value is approximately the same then the problem is most likely the calibration potentiometer or the movement in the meter. The old probe removed is probably good! Call Alcor for repair of meter.
Is there any way I can test a thermocouple without expensive equipment?
Yes, by using an ALCAL 2000EGT/CHT System Tester. If not available then measure the loop resistance (see resistance table) of the probe with a digital multi-meter, if available. While viewing display, move probe wire to detect internal wire breaks. If the reading is steady then the probe is probably good. When heated to just turning red, the temperature is about 1550-1650°F.
Alcor P/N | Type | Color | Resistance @ 70°F | Millivolts at 1550-1650°F | Weight | Size |
All Clamp | K | Red/Yellow | .6 -1.0 ohm | 34.12 - 36.36 mV | .12 lbs | 3.25 max dia. |
All Screw-in | K | Red/Yellow | .6 -1.0 ohm | 34.12 - 36.36 mV | .12 lbs | call |
All Clamp | E | Red/Brown | .7 -1.0 ohm | 63.04 - 67.33 mV | .12 lbs | 3.25 max dia. |
All Screw-in | E | Red/Brown | .8 -1.1 ohms | 63.04 - 67.33 mV | .12 lbs | call |
Alcor , Inc. warrants all parts in all new Alcor, Inc. products to be free from defects in material and workmanship under normal use and under the following conditions: Alcor , Inc.'s obligation under this warranty is limited to the repair or exchange of any defective part, if the part is returned and return shipping prepaid, within FIVE YEARS of the date of manufacture for grounded thermocouples and within ONE YEAR of the date of manufacture for ungrounded thermocouples.
Questions concerning all Alcor, Inc.'s products should be directedto Customer Support at 1-800-FLI-SAFE (1-800-354-7233) or email: support@alcorinc.com.
FAA-PMA/STC SA 522 SW: This product is FAA approved for installation on ALL piston engine aircraft. After installation of complete system, return aircraft to service via Form 337 referencing STC SA 522 SW. This is not required for replacement parts. All piston powered aircraft, regardless of make, are covered by this STC.
Take a Flight to Our Web Site
www.alcorinc.com
300 Breesport
San Antonio, Texas 78216
Phone 210/349/6491
Fax 210/308/8536
Toll free 800/354/7233
Web site: www.alcorinc.com
E-Mail: support@alcorinc.com
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Need help?
Do you have a question about the EGT Probe and is the answer not in the manual?
Questions and answers