Sharp AY-XPC12ZU Operation Manual page 8

Table of Contents

Advertisement

Available languages

Available languages

SAFETY PRECAUTIONS (Continued)
tion equipment being used is suitable for use with all applicable refrigerants, i. e.
non-sparking, adequately sealed or intrinsically safe.
‡ 3UHVHQFH RI ¿UH H[WLQJXLVKHU ,I DQ\ KRW ZRUN LV WR EH FRQGXFWHG RQ WKH UHIULJHUDW-
LQJ HTXLSPHQW RU DQ\ DVVRFLDWHG SDUWV DSSURSULDWH ¿UH H[WLQJXLVKLQJ HTXLSPHQW
VKDOO EH DYDLODEOH WR KDQG +DYH D GU\ SRZGHU RU &2 ¿UH H[WLQJXLVKHU DGMDFHQW
to the charging area.
‡ 1R LJQLWLRQ VRXUFHV 1R SHUVRQ FDUU\LQJ RXW ZRUN LQ UHODWLRQ WR D 5()5,*(5$7-
,1* 6<67(0 ZKLFK LQYROYHV H[SRVLQJ DQ\ SLSH ZRUN VKDOO XVH DQ\ VRXUFHV RI
LJQLWLRQ LQ VXFK D PDQQHU WKDW LW PD\ OHDG WR WKH ULVN RI ¿UH RU H[SORVLRQ $OO SRV-
VLEOH LJQLWLRQ VRXUFHV LQFOXGLQJ FLJDUHWWH VPRNLQJ VKRXOG EH NHSW VXI¿FLHQWO\ IDU
away from the site of installation, repairing, removing and disposal, during which
refrigerant can possibly be released to the surrounding space. Prior to work tak-
ing place, the area around the equipment is to be surveyed to make sure that
WKHUH DUH QR ÀDPPDEOH KD]DUGV RU LJQLWLRQ ULVNV ³1R 6PRNLQJ´ VLJQV VKDOO EH
displayed.
‡ 9HQWLODWHG DUHD (QVXUH WKDW WKH DUHD LV LQ WKH RSHQ RU WKDW LW LV DGHTXDWHO\ YHQ-
tilated before breaking into the system or conducting any hot work. A degree
of ventilation shall continue during the period that the work is carried out. The
ventilation should safely disperse any released refrigerant and preferably expel it
externally into the atmosphere.
‡ &KHFNV WR WKH UHIULJHUDWLQJ HTXLSPHQW :KHUH HOHFWULFDO FRPSRQHQWV DUH EHLQJ
FKDQJHG WKH\ VKDOO EH ¿W IRU WKH SXUSRVH DQG WR WKH FRUUHFW VSHFL¿FDWLRQ $W DOO
times the manufacturer's maintenance and service guidelines shall be followed.
If in doubt, consult the manufacturer's technical department for assistance.
The following checks shall be applied to installations using FLAMMABLE RE-
)5,*(5$176
± WKH DFWXDO 5()5,*(5$17 &+$5*( LV LQ DFFRUGDQFH ZLWK WKH URRP VL]H ZLWKLQ
which the refrigerant containing parts are installed;
– the ventilation machinery and outlets are operating adequately and are not
obstructed;
– if an indirect refrigerating circuit is being used, the secondary circuit shall be
checked for the presence of refrigerant;
– marking to the equipment continues to be visible and legible. Markings and
signs that are illegible shall be corrected;
– refrigerating pipe or components are installed in a position where they are
unlikely to be exposed to any substance which may corrode refrigerant contain-
ing components, unless the components are constructed of materials which are
inherently resistant to being corroded or are suitably protected against being so
corroded.
‡ &KHFNV WR HOHFWULFDO GHYLFHV 5HSDLU DQG PDLQWHQDQFH WR HOHFWULFDO FRPSRQHQWV
shall include initial safety checks and component inspection procedures. If a fault
exists that could compromise safety, then no electrical supply shall be connected
to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected
immediately but it is necessary to continue operation, an adequate temporary
solution shall be used. This shall be reported to the owner of the equipment so
all parties are advised.
Initial safety checks shall include:
– that capacitors are discharged: this shall be done in a safe manner to avoid
OM-B142 ZU A5 EN.indd 6
EN-6
2022/7/22 10:59:13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents