2.3
Optional: ADLS Junction Box (Part #
(Aircraft Detection Lighting Systems)
2.3.1
JB mounting
The ADLS junction box (JBWT-ADLS) is typically installed at the base of a structure or within
wind turbine nacelle. The junction box has mounting feet 8.39"x 13.08". Refer to details on the
Chassis layout drawing toward the back of this manual.
2.3.2
JB electrical connection
Route your specific Electrical power input through the base of enclosure by a ¾" NPT hub.
Installation should be in accordance with local methods and National Electrical Codes (NEC).
2.3.3
JB beacon connections
Maximum of two REDSTAR cable glands entries are available through the base of the enclosure
with terminal connections for power, data, and alarms.
2.3.4
JB alarm monitoring connection
One alarm entry through base of enclosure is for monitoring beacon to indicate if light has failed
through a relay prewired to normally closed. Normally open is available within REDSTAR base
pcb, see operation section.
2.3.5
JB Ethernet connection
One RJ45 Ethernet connection is at base of enclosure for ADLS communications.