Œ
Each ADVANTAGE Hookup is comprised of multiple ports and connector assemblies.
Each port is labeled with a Port ID number (circled). This same number also identifies the
corresponding Connector Assembly.
CONNECTOR ASSEMBLY IDENTIFICATION CHART
Port ID
Port Name
Connector Assembly Description
LEAK TEST
Leak Test Connector Assembly
JET/AUX
Air/Water Connector Assembly
BIOPSY
Biopsy Inlet Connector Assembly
AIR
Air Probe Connector Assembly
ELEVATOR
Auxiliary Water Connector Assembly
WATER
Air/Water Connector Assembly
SUCTION
Suction Connector Assembly
EXTRA
N/A
If a Connector Assembly needs replacement, locate the port number/name and use
the corresponding order number found in the chart above. Connector Assemblies are
specific to individual hookups.
If you have any questions regarding this hookup, in the U.S., please contact
MEDIVATORS Technical Support at 1-800-444-4729. Outside the U.S., please contact
your MEDIVATORS Distributor.
© 2015 Medivators Inc. 50098-850-EN/B

Suction Connector
Align and insert the end of the connector into the
suction valve port. Firmly push the connector until
it 'clicks', then push the "LOCK" button until there
is another 'click'. To remove, press the "RELEASE"
latch (make sure the "LOCK" button pops up). Tilt
the connector towards the V-notch of the scope
port while pulling the connector out.
Biopsy Connector
Align the biopsy connector
disc over the biopsy inlet
Order Number
and push down to compress
H28210-1
spring and slide the frame
forward to fully engage.
NA
H28210-3
NA
DESIGNATED HOOKUP FOR THE FOLLOWING ENDOSCOPES*:
NA
NA
BF-30
BF-240AWY1
BF-40
BF-260
H28210-7
BF-140
BF-6C240
BF-160
BF-6C260
N/A
BF-180
BF-MP160
BF-200
BF-MP160F
BF-240
BF-MP60
* This list of corresponding endoscope models is subject to change without notice. For a full list, please go to:
www.medivators.com/hookuplookup
Representative endoscope for illustrative purposes only. For exact
port locations, refer to endoscope manufacturer's instruction guide.
READ ALL INSTRUCTIONS PRIOR TO CONNECTION
Locate the endoscope port and follow the instructions for attaching the
corresponding Endoscope Connector. All connectors must be attached.
BF-P30
BF-P200
BF-1T30
BF-1T180
BF-P40
BF-P240
BF-1T30D
BF-1TQ180
BF-P60
BF-P290
BF-1T40
BF-1T200
BF-P150
BF-Q180-AC
BF-1T60
BF-1T240
BF-P160
BF-Q190
BF-1T130
BF-1T260
BF-P180
BF-TE2
BF-1T150
BF-Q180
BF-P190
BF-XP160
BF-1T160
BF-XT30
Leak Test Connector
Align the slot on connector
with the pin on the scope.
Push on and turn clockwise
to engage.
BF-XT40
ENF-VT
BF-XT160
ENF-VT2
BF-F260
LTF-160
BF-H190
LTF-240
BF-XP190
MAF-TM
BF-1TH190
BF-P260F

Advertisement

loading

Summary of Contents for Cantel Medical Medivators BF-30

  • Page 1 2-8-210 READ ALL INSTRUCTIONS PRIOR TO CONNECTION HOOKUP CONNECTION GUIDE Using MEDIVATORS ® ADVANTAGE ® Automated Endoscope Reprocessors Locate the endoscope port and follow the instructions for attaching the corresponding Endoscope Connector. All connectors must be attached. ADVANTAGE HOOKUP DIAGRAM ...
  • Page 2 - identifier of port location in ADVANTAGE system. Error logs identify issues using these names. Also identifier of Connector Assembly replacements for Manufactured in the USA by: older model hookups. Cantel Medical Devices (China) Co. Ltd. Medivators Inc. Medivators BV Cantel Medical Asia/Paci c Pte. Ltd.

This manual is also suitable for:

Medivators bf-240awy1Medivators bf-p30Medivators bf-p200Medivators bf-1t30Medivators bf-1t180Medivators bf-xt40 ... Show all