Items to check

Check
Are the indoor units installed
securely?
Has an inspection been made to
check for gas leakage?
Has complete thermal insulation
been done (gas pipes, liquid
pipes, indoor portions of the drain
hose extension)?
Is the drainage secure?
Are the earth wire connections
secure?
Are the electric wires connected
correctly?
Is the wiring in accordance with
the specifications?
Are the inlets/outlets of the indoor
and outdoor units free of any
obstructions?
Are the stop valves open?
Do the marks match (room A,
room B) on the wiring and piping
for each indoor unit?
Is the priority-room setting set for
2 or more rooms?
ATTENTION
Have the customer actually operate the unit while
looking at the manual included with the indoor unit.
Instruct the customer how to operate the unit correctly
(particularly cleaning of the air filters, operation
procedures, and temperature adjustment).
Even when the air conditioner is not operating, it
consumes some electric power. If the customer is not
going to use the unit soon after it is installed, turn OFF
the breaker to avoid wasting electricity.
D
ISPOSAL REQUIREMENTS
Dismantling of the unit, treatment of the refrigerant, of oil and of other
parts must be done in accordance with relevant local and national
legislation.
Installation manual
11
Symptom
Falling, vibration, noise.
No cooling, no heating.
Water leakage.
Water leakage.
Danger in case of an earthing
fault.
No cooling, no heating.
Operation failure, burning.
No cooling, no heating.
No cooling, no heating.
The priority-room setting will not
function.