Portable Power Station Model NO.: EA5000-5120Wh-1BK Product Instruction Manual Please read the instructions carefully before use and follow the instructions CEA Electric Co., Ltd...
CONTENT I、Product Use and Function Introduction ......1 Ⅱ、Product Introduction .......... 3 1. Product Main Structure Composition ....错误!未定义书签。 2. Panel Function Description ....... .3-5 3. Display Interface Description ......5-10 Ⅲ、Technical Parameters ......... 11 Ⅳ、Operation and Usage .......... 12 1. Steps for the First Start of Portable Power Station ..12 2.
I、Product Use and Function Introduction Product Name: Potable Power Station Model/Specification: EA5000-5120Wh-1BK Application and Function Introduction: Transform LiFePO4 DC to AC sine wave by inverter. When the product is out of power, it can be charged by mains and PV. Without Mains, this product can output AC to charge...
Page 4
use. The product has functions like output overload, short circuits, and high temperature.
II. Product Introduction 1. Product Main Structure Composition The portable power station is mainly composed of a metal protection frame, metal shell, PV reverse control machine, touch screen, USB/DC panel, LiFePO4 battery, and other main accessories. 2. Panel Function Description 2.1 Front Panel LCD Touch Screen DC5521...
Page 6
2.2 Rear Panel Cooling Window AC Charging Input Socket 20A PV Charging Input Socket Expandable Battery Interface Ground Post 2.3 Left Door Storage Bag...
2.4 Right Door Ac Output, PV Input Circuit Breaker 3. Display Interface Description 3.1 Home Page Parameter Total Battery Level Expandable Setting Button Battery Information Button Back Home Charging Input Button Status and Parameters Page Remaining Button Charging Time Load Output and Parameters Remaining Page Button...
Page 8
3.2 Battery Information Page The battery includes five status:1. Disconnected,2. Standby: the battery is connected and on standby,3. Charging: the battery is connected and charging, 4. Discharge: the battery is connected and discharged, 5. Failure. Main Battery Power Level Expandable Main Battery Battery Status...
Page 9
3.4 Load Output Page USB/DC Load AC Load Output Output Parameters Parameters Display Display 3.5 Setup Page Return to Previous Page Button Charging Language Setting History Screen Brightness Set the Screen Setting Sleep time Touch Sound Fault Code Switch Display...
Page 10
3.6 Language Settings Page The product supports three language settings: English, French, Spanish (the default setting is English); 3.7 Screen Sleep Time Page There are four Settings for the off time: 30 seconds, 1 minute, 5 minutes, and never (the default setting is 5 minutes); 3.8 Charging History Page...
Page 11
The charging history record will save the charging capacity record of the previous seven days, and display the record according to the total charging power (Ah) of each day. In that case, only the data of seven days is displayed. 3.9 The Fault Icon Instructions Fault icons are divided into high temperature, short circuit, and overload.
Page 12
Short Circuit Fault Icon Output Overload Icon 3.10 Fault Code Display The fault code can display four fault numbers at the same time, increasing from left to right. See Chapter 5 (Failure Code description table) for details about the meaning of the code.
III. Technical parameters Item Parameter Nominal Power Peak Power 10KW On-load Motor Capability Battery Parameters LiFePo4 51.2V 100AH Battery Expansion Supports the parallel expansion of up to 6 battery packs Grid Connection Product Size 840*750*872mm Product Weight 138.5KG Ambient Temperature Range -10-40℃...
Independent 100W Output*2: 5V3A 9V3A 12V3A Output 15V3A 20V5A Support PPS/PD/QC3.0/QC2.0/AFC USB-C*2 Output /FCP/BC1.2/APPLE and other fast charging protocols 5521 interface*2, cigarette lighter socket*1 DC Output 12V10A American standard socket L5-30*1 30A 125V AC Output 60HZ American standard socket TT-30R*1 30A,125V, AC Output 60HZ American standard socket duplex GFCI 5-20R*3...
1.3 Fix the grounding post on the back of the station to the ground. 1.4 Press the “POWER” button on the front panel, and if the green light comes on, it indicates that the startup has been successful. Observe whether the battery on the screen is fully charged. When the battery level is below 30%, it is recommended to fully charge it before use.
the photovoltaic charging power and remaining charging time displayed on the screen correspond to the product parameters. During the charging process, the POWER switch must be turned on. Otherwise, the product cannot be charged. 3. AC Output On-load Usage: AC on load: Before use, please check that the power range and voltage range of the on-load electrical equipment should match the output parameters of the equipment, and press the RESET button on the GFCI5-20R socket to open it;...
Page 17
as those of the main battery. When the main and the expandable battery are off, insert one end of the expandable battery cable into the battery expansion port on the rear panel of the station and the other end into the socket in the expandable battery.
V、Fault Code Comparison Table Fault Meaning Description Codes BatVoltLow Battery under-voltage alarm Battery discharge average current BatOverCurrSw overcurrent software protection BatOpen Battery not connected alarm BatLowEod Battery under-voltage stop discharge alarm BatOverCurrHw Battery overcurrent hardware protection BatOverVolt Charge overvoltage protection BusOverVoltHw Bus overvoltage hardware protection BusOverVoltSw...
Page 19
OverTemperMppt PV radiator over temperature protection Over-temperature protection of inverter OverTemperInv heat sink FanFail Fan failure EEPROM Memory failure ModeNumErr Model setting error Positive and negative bus voltage Busduff imbalance BusShort Bus short circuit Inverted AC output backflow to bypass AC RlyShort output LinePhaseErr...
BMSUnderVolt BMS under-voltage alarm BMSOverVolt BMS overvoltage alarm 、Product Maintenance Ⅵ 6.1 Newly purchased products should be fully charged before use; 6.2 Regularly remove dust and dirt from the cooling window; In the case of long-term storage for more than three months, not less than 50% of the power storage shall be maintained;...
Page 21
C、Check whether the specifications and models of the charging cable are consistent with those equipped with this power station and check whether there is an open circuit. D、When charging, the AC output socket should not be plugged into the load, otherwise, it cannot start charging.
Page 22
B、The circuit breakers at the side door of the product should all be turned C、The RESET button on the GFCI5-20R socket should be turned on and the green indicator should be lighting. D、Confirm whether the power of the load appliance is within the normal load range of the power station.
Page 23
C. Check whether the plug of the expansion connection line is completely inserted into the expansion socket; D. Measure and exclude whether the expansion line has an open circuit situation;...
、Warnings and Precautions Ⅷ 8.1 Different electrical appliances have different voltage standards. Before use, please carefully check whether the rated voltage range of the product is consistent with the voltage range of the portable power supply, otherwise, it may lead to dangerous situations; After the battery is discharged to the cut-off voltage, continuing to discharge is called over-discharge.
Page 25
8.9 Do not drop, squeeze or collide with the product, so as not to subject the product to external pressure, which may cause a short circuit of the internal circuit of the product and damage to the battery; 8.10 After use, please turn off the machine in time (the no-load power consumption will continue to consume battery power when the machine is on);...
Page 26
8.16 When transporting and lifting products, it is necessary to ensure that the lifting rings are tightly and firmly installed, otherwise safety accidents may occur; 8.17 When using the expandable battery, ensure the deviation range of the battery capacity between batteries is within 10%. Batteries of different specifications and manufacturers cannot be used;...