Advertisement

Quick Links

Table of Content SCE-HE08W120V
..................................................................................................................................
.........................................................................................................................................
..............................................................................................................................
.....................................................................................................................................
Version No. 1-5 - 19.11.2023
.........................................................................................................................
......................................................................................................................
.....................................................................................................................
......................................................................................................................
.....................................................................................................................
...................................................................................................................
............................................................................................................
........................................................................................................................
.............................................................................................................
.....................................................................................................................
.........................................................................................................
................................................................................................................
Doc. No. 99580141001SG
..........................................................................
2
3
4
5
8
8
9
10
11
12
13
14
15
15
15
16
17
1 / 17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCE-HE08W120V and is the answer not in the manual?

Questions and answers

Summary of Contents for SCE SCE-HE08W120V

  • Page 1: Table Of Contents

    Table of Content SCE-HE08W120V 1. User manual ..........................2. Legal regulations ......................... 3. Safety instructions ........................4. Settings ............................5. Functional principle ........................6. Technical data ..........................7. Performance graph ........................8. Mounting ............................. 9. Mounting Principle ........................10. Cut Out Dimension ........................
  • Page 2: User Manual

    1. User manual This instruction manual contains information and instructions to enable the user to work safely, correctly and economically on the unit. Understanding and adhering to the manual can help one: Avoid any dangers. Reduce repair costs and stoppages. Extend and improve the reliability and working life of the unit.
  • Page 3: Legal Regulations

    2. Legal regulations Liability The information, data and instructions contained in this instruction manual are current at the time of going to press. We reserve the right to make technical changes to the unit in the course of its development. Therefore, no claims can be accepted for previously delivered units based on the information, diagrams or descriptions contained in this manual.
  • Page 4: Safety Instructions

    3. Safety instructions Upon delivery the unit is already meeting current technical standards and can therefore be safely taken into operation. Only authorised personnel is allowed to work on the unit. Unauthorised personnel must be prohibited from working on the unit. Operating personnel must inform their superiors immediately of any malfunction of the unit.
  • Page 5: Settings

    4. Settings Air-air heat exchangers are intended as complementary accessories to large industrial equipment which include a motor-operated fan or blower together with a heat exchanger module. These may also include an electric heater. The fan or blower is intended to recirculate air and allow heat exchange. The heat exchanger is designed for air heat transfer only.
  • Page 6 Programming The operating parameters can be modified using the front keypad. Access differs depending on the type of parameter. Access to configuration parameters is protected by a password that prevents unwanted modifications or access by unauthorised persons. Setting cooling set point, St1: 1.
  • Page 7 duration of 4 minutes. “SET+▲” tests cooling relays. “SET+▼” tests Alarms and Heater relays Important Notes Whilst programming, if no button is pressed for 10 seconds, the display starts flashing, and after 1 minute returns to the main display without saving changes. To increase scrolling speed, press and hold the ▲...
  • Page 8: Functional Principle

    5. Functional principle 6. Technical data Order Number SCE-HE08W120V Heat exchanger performance 8 W/F Operating Temperature Range 23°F - 131°F Ambient air circuit: 119 / 300 m³/h Air flow volume (system / unimpeded) Cabinet air circuit: 96 / 300 m³/h...
  • Page 9: Performance Graph

    7. Performance graph Version No. 1-5 - 19.11.2023 Doc. No. 99580141001SG 9 / 17...
  • Page 10: Mounting

    8. Mounting Danger from electrical voltage The unit must be mounted by specialist personnel (qualified electricians). The personnel must ensure that the cabinet is disconnected from the electrical supply for the duration of the mounting operation. Therefore take the cabinet out of operation, following the relevant instructions before mounting work commences. Danger through incorrect work on the unit.
  • Page 11: Mounting Principle

    9. Mounting Principle Heat exchanger Mounting gasket Slotted stud M6 x 25 mm Enclosure Washer A6.4 M6 Lock nut Version No. 1-5 - 19.11.2023 Doc. No. 99580141001SG 11 / 17...
  • Page 12: Cut Out Dimension

    10. Cut Out Dimension Version No. 1-5 - 19.11.2023 Doc. No. 99580141001SG 12 / 17...
  • Page 13: Dimension (H X W X D)

    11. Dimension (H x W x D) Version No. 1-5 - 19.11.2023 Doc. No. 99580141001SG 13 / 17...
  • Page 14: Wiring Diagram

    12. Wiring Diagram Power connector Alarm (NO) Alarm (COM) Alarm (NC) Door contact Door contact Version No. 1-5 - 19.11.2023 Doc. No. 99580141001SG 14 / 17...
  • Page 15: Taking Into Operation

    13. Taking into Operation As described before the unit is controlled in relation to the cabinet internal temperature. The required cabinet temperature can be set on the potentiometer on the controller.The temperature adjustment range is between 0°C (left-hand stop) and 60°C (right-hand stop). The thermostat is pre-set at 35°C. To adjust the cabinet internal temperature proceed as follows: Remove the MCB access plate on the front of the unit.
  • Page 16: Transport & Storage

    16. Transport & Storage Malfunction due to transport damage On delivery the carton containing the unit must be examined for signs of transport damage. Any transport damage to the carton could indicate that the unit itself has been damaged in transit which in the worst case could mean that the unit will not function.
  • Page 17: Parts Supplied / Spare Parts / Accessories

    M6 nuts Drain pipe Silicone washer Drain fitting Female connector Saginaw Control and Engineering 95 Midland Road Saginaw, MI 48638 Phone: 989 / 799-6871 Fax: 989 / 799-4524 sce@saginawcontrol.com Version No. 1-5 - 19.11.2023 Doc. No. 99580141001SG 17 / 17...

Table of Contents