spring guide disc is in its correct position (fig. 13)
- Remount the diffuser attaching it to the upper hole
IV – DISABLING THE PRESSURE REGULATOR
- Remove the protective lid
- Regulate the supply calibration screws so that the maximum
amount of gas can pass (disk completely horizontal)
After regulating seal the lid with paint, lacquer or other such
materials.
Note: It is necessary to use a pressure regulator that operates at
30 mbar for Butane Gas and at 37 mbar for Propane Gas.
The above values must be measured using a barometer con-
nected to the devices pressure entrance.
TRANSFORMATION FROM LPG TO METHANE GAS
Execute operations I, II and III described above
Fig. 6
Fig. 9
Fig. 12
IV – ENABLING THE PRESSURE REGULATOR
- Remove the protective lid
- Regulate the pressure screws so that the burner reaches the
pressure levels indicated on the technical data on page 4 .
Note: ensure that the gas pressure is at 20 mbar.
Fig. 7
Fig. 10
Fig. 13
8
After regulating seal the lid with paint, lacquer or other such
materials.
Check that all the disassembled parts are perfectly sealed
once the device is operational using a soapy solution.
WARNING – IMPORTANT Write on adhesive paper "device
transformed", including the date of the operation, the name
and signature of the person who performed the transforma-
tion and attach it to the device near the older information pla-
te.
In addition attaché the "Transformed Gas to..." sticker.
Attach it to the device over the previous similar sticker, on the
frontal part of the hood.