Maintenance - Schneider Airsystems CPM 170-8-2 WOF Original Operating Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
GB
CPM 170-8-2 W-oilfree
Table of contents - Part 1
1.1
Scope of delivery ......................
1.2
Conventional use ......................
1.3
Technical data ..........................
1.4
Components.............................
1.5
Adjusting the working pressure...
1.6

Maintenance.............................

1.7
Vessel inspections .....................
1.1 Scope of delivery
– Compressor with instruction manual
1.2 Conventional use
The compressor is designed for generating
and storing compressed air only. Com-
pressed air is only suitable for compressed
air tools/devices/machines.
Any other type of use is considered contrary
to the intended use.
The compressor must not be used in poten-
tially explosive areas. Combustible, caustic
or toxic gases must not be sucked in!
1.3 Technical data
see Fig. 1a
1.4 Components
01
Compressor unit
02
Intake filter
07
Check valve
08
Vessel
09
Condensate drain valve
10
Pressure switch with ON/OFF switch
11
Safety valve
I/2
12
Pressure gauge (vessel pressure)
13
Pressure gauge (working pressure)
2
14
Electric motor
2
18
Pressure reducer
2
19
Quick-action coupling (clean, regu-
lated compressed air)
2
2
1.5 Adjusting the working pres-
sure
2
Rotate clockwise = pressure is increased.
2
Rotate anticlockwise = pressure is reduced.
1.6 Maintenance
1.6.1
Cleaning the intake filter
1. Loosen the screws and open the housing
as shown in Fig. 5a.
2. Pull out the filter insert. (Fig. 5a)
3. Clean the filter insert using the blow gun,
exchange the filter insert if necessary.
4. Insert the filter insert.
5. Close the housing and tighten the
screws.
1.7 Vessel inspections
No inspections are specified for the ves-
sels.
We recommend that a "qualified person"
perform a pressure test on the vessel, de-
pending on its rate of utilisation, after 10
years in accordance with the Ordinance on
Industrial Safety and Health. Contact any of
our service partners.
The statutory specified inspections must
be arranged in accordance with the appli-
cable regulations of the respective coun-
try in which the vessel is used.

Advertisement

Table of Contents
loading

This manual is also suitable for:

A 201 000

Table of Contents