Summary of Contents for Gunnebo DL645

  • Page 1 Operation and Maintenance Manual DL645 Simplex 45 M00000118-E-uk – 06.07 DL645 and Simplex 45...
  • Page 2 Document history Rev. Date Aut. Description Page Section 27/10/2004 First issue 10/12/2004 28/01/2005 30/03/2007 Simplex 45 ATT added; full document review 06/06/2007 Simplex 45 ATT schematics reviewed M00000118-E-uk – 06.07 DL645 and Simplex 45...
  • Page 3: Table Of Contents

    Counting pulse and other output signals..........19 SECTION 4 Technical Information Components Location................. 20 Hercules Mechanism Construction ............ 21 Die Cast Base..................21 Rotary Unit..................21 Locking Device ................... 22 Positioning Device ................23 Damper ....................23 M00000118- E-uk – 06.07 DL645 and Simplex 45...
  • Page 4 Table 8.2 Trimmer TR2 (Reader management)......... 54 Table 8.3 Trimmer TR3 (Timings) ............55 Table 8.4 Trimmer TR4 (Authorizations stacking, Counting pulse sequence)..............55 Table 8.5 Trimmer TR5 (REL2, REL3, Traffic Lights) ......56 M00000118- E-uk – 06.07 DL645 and Simplex 45...
  • Page 5 Table 8.7 Trimmer TR7 (Mode A and B, Remote Controls) ..................... 58 Table 8.8 Trimmer TR8 (REL1)............58 Table 8.9 LL2001 dip-switches configuration for RS485 serial line address assignment ............59 SECTION 9 Declaration of Conformity ............... 60 M00000118- E-uk – 06.07 DL645 and Simplex 45...
  • Page 6: Introduction

    Telephone +44 (0) 1825 746105. Proprietary Notices All data appearing herein is of a proprietary nature, with exclusive title to it held by Gunnebo Entrance Control. The possession of this Manual and the use of the information is therefore restricted only to those persons duly authorized by Gunnebo Entrance Control.
  • Page 7: General Condition Of Use

    Use only the correct tools for the task in hand. When working on the equipment, remove any personal jewellery that may be conductive, or clothing that may become entangled with mechanical parts. M00000118- E-uk – 06.07 DL645 and Simplex 45...
  • Page 8: Equipment Safety Systems

    Site Personnel within the Vicinity of the Work Area Hazard Fume Inhalation Current Controls Compliance with health regulations Rating 5: Commissioning Who is at Risk Site Engineer Hazard Power Supply/Moving Parts Current Controls Isolate Power M00000118- E-uk – 06.07 DL645 and Simplex 45...
  • Page 9: Ce - Marking

    The Gunnebo Entrance Control Hercules-Lite Tripods is a security product, any children or minors using the turnstile must be supervised and accompanied by a responsible adult. Gunnebo Entrance Control does not accept any liability if this rule is not enforced. M00000118- E-uk – 06.07...
  • Page 10: Product Description

    Section 2 Product Description The Gunnebo Entrance Control Hercules-Lite Tripod range is designed for applications where an high flow rate is required maintaining a high degree of security. General Details Figure 2.1 DL645 turnstile M00000118- E-uk – 06.07 DL645 and Simplex 45...
  • Page 11 Figure 2.2 Simplex 45 turnstile M00000118- E-uk – 06.07 DL645 and Simplex 45...
  • Page 12 Figure 2.3 Simplex 45 ATT turnstile M00000118- E-uk – 06.07 DL645 and Simplex 45...
  • Page 13: Technical Details

    In this mode the MTBF is increased from 1.5 to 2.5 million cycles and increases passage through-put speed. Power Supply: 115/230 Vac 50/60Hz M00000118- E-uk – 06.07 DL645 and Simplex 45...
  • Page 14 ‘Drop Arm’ features. • One serial port – RS485 Operating Temperature: 0 to 45°C Transportation and Storage: -25 to +55° C Relative Humidity: 95% Non condensing. M00000118- E-uk – 06.07 DL645 and Simplex 45...
  • Page 15: Instruction For Use

    (or the rotor’s cabinet) is to the right when passing through the turnstile. Direction A Direction B Solenoid A Solenoid B Head Assembly Figure 3.1 Schematic Diagram of the Unit. M00000118- E-uk – 06.07 DL645 and Simplex 45...
  • Page 16: Operating Modes

    (see Section 8 - table 8.7); • remote control (optional Gunnebo Entrance Control MP2000 control module); • RS485 serial interface (through the Gunnebo Entrance Control proprietary serial protocol). The action of the Remote Control or the Serial Control has priority over the trimmers position setting.
  • Page 17: Normally Open Transit Sequence

    If this optional are used, a trimmer of the LL2001 electronic board must be properly configured (see Section 8 – table 8.5). M00000118- E-uk – 06.07 DL645 and Simplex 45...
  • Page 18: Alarms

    The Hercules-Lite turnstile control logic offers an electrical interface in order to allow the remote control of entrance. By means of the optional Gunnebo Entrance Control MP2000 control module, the operation modes of the unit can be set by a remote consol (see connection details is Section 5 of this manual).
  • Page 19: Programmable Parameters And Trimmers

    The maximum number of authorisation signals that can be recorded is determined by the TR4 trimmer position. See also section 5 for connection details. M00000118- E-uk – 06.07 DL645 and Simplex 45...
  • Page 20: Counting Pulse And Other Output Signals

    It signals that the gate is powered on. ‘alarms’: It signals an alarm condition with the permanent activation of the output. ‘buzzer’ It signals an alarm condition with the intermittent activation of the output M00000118- E-uk – 06.07 DL645 and Simplex 45...