barbas 70-55 PF2 Preparation Manual

Gas fire panorama
Hide thumbs Also See for 70-55 PF2:
Table of Contents

Advertisement

Quick Links

Preparation manual
Gas Fire Panorama 70-55 PF2
Serial number:
Production date:

Advertisement

Table of Contents
loading

Summary of Contents for barbas 70-55 PF2

  • Page 1 Preparation manual Gas Fire Panorama 70-55 PF2 Serial number: Production date:...
  • Page 2 Barbas Bellfires BV. This document could contain technical inaccuracies or typographical errors. Barbas Bellfires BV reserves the right to revise this document from time to time in the contents thereof.
  • Page 3: Table Of Contents

    Gas Fire Panorama 70-55 PF2 with 6 cm frame and convection casing........28 Gas Fire Panorama 70-55 PF2 with 10 cm frame..............29 Gas Fire Panorama 70-55 PF2 with 10 cm frame and convection casing.........30 Gas Fire Panorama 70-55 PF2 with 10 cm frame and adjustable legs........31 5.10 Operating unit..........................32 5.11...
  • Page 4 Contents Available components for the concentric flue system - natural draught......................33 Appliance part list........................33 Bellfires - Muelink & Grol system Ø100 - Ø150................. 34 Bellfires - Muelink & Grol system Ø130 - Ø200................. 40 Poujoulat - DUOGAS system Ø100 - Ø150................44 Poujoulat - DUOGAS system Ø130 - Ø200................
  • Page 5: About This Document

    • Preparation for installation This document refers to the Gas Fire Panorama 70-55 PF2 as 'the appliance'. This document is an essential part of your appliance. Read it carefully before you do work on the appliance. Keep it in a safe place.
  • Page 6: Overview Of The Concentric Flue System

    Overview of the concentric flue system Overview of the concentric flue system The concentric flue system provides the appliance with combustion air and removes the flue gases from the appliance. The concentric flue system is made of these items: Item Description Concentric flue The concentric flue is a pipe with an inner pipe.
  • Page 7: Safety

    - Part 1: System chimney products ). Concerns building materials according to DIN 18160 Chimney systems. For installation and use of the Opti-Vent system refer to the Barbas manual "installation and mainte- nance manual Opti-Vent system. Gas Fire Panorama 70-55...
  • Page 8: Requirements

    Requirements Requirements Requirements on the location • Never use combustible building materials for the fireplace. • Do not install the appliance against a flammable rear wall. • Install a non-flammable insulation plate of at least 12 mm between the appliance and a non-flammable rear wall.
  • Page 9: Requirements On The Roof And Wall Outlet

    Requirements Requirements on the roof and wall outlet Location of roof and wall outlets Refer to the table hereunder for explanation of the figure. Note: All the minimum distances in the table are guidelines. Consult your national and local regulations for the exact minimum distances. Gas Fire Panorama 70-55...
  • Page 10 Requirements Minimum separation distances for roof and wall outlet(terminal) in mm Minimum Location distance [mm] Below an opening on the same wall/roof 2000 Above an opening on the same wall/roof Horizontally to an opening on the same wall/roof Horizontally to a facing opening in a opposite wall 2000 From a roof terminal under an opening...
  • Page 11: Requirements On The Concentric Flue System

    Requirements Requirements on the concentric flue system Caution: • Make sure that no flammable materials are located close to the flue system. The outer walls of the flue system can be 150 °C. • Make sure that the concentric flue system is in a casing. •...
  • Page 12: Possibilities For A Concentric Flue System With A Roof Outlet

    Requirements 4.5.1 Possibilities for a concentric flue system with a roof outlet Rigid concentric flue systems Note: Refer to chapter for a description of the numbers in the figures. 10/11/12/13 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appli- Concentric connection on the appli-...
  • Page 13 Requirements 14,15 10/11/12/13 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection Concentric connection (min. - max.) (min. - max.) (min. - max.) on the appliance is on the appliance is Ø100-Ø150 mm Ø130-Ø200 mm 1.0 - 11.0 m...
  • Page 14 Requirements Flexible concentric flue systems 10/11/12/13 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appli- Concentric connection on the appli- (min. - max.) ance is Ø100-Ø150 mm ance is Ø130-Ø200 mm 2.0 - 4.0 m 30 mm 65 mm...
  • Page 15 Requirements ≥45° 10/11/12/13 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection Concentric connection (min. - max.) (min. - max.) (min. - max.) on the appliance is on the appliance is Ø100-Ø150 mm Ø130-Ø200 mm 1.0 - 11.0 m...
  • Page 16 Requirements 27,28,29 26,29 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appli- Concentric connection on the appli- (min. - max.) ance is Ø100-Ø150 mm ance is Ø130-Ø200 mm 2.0 - 4.0 m 30 mm 65 mm...
  • Page 17 Requirements ≥45° 27,28,29 26,29 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection Concentric connection (min. - max.) (min. - max.) (min. - max.) on the appliance is on the appliance is Ø100-Ø150 mm Ø130-Ø200 mm 1.0 - 11.0 m...
  • Page 18: Possibilities For A Concentric Flue System With A Wall Outlet

    Requirements 4.5.2 Possibilities for a concentric flue system with a wall outlet Note: Refer to chapter for a description of the numbers in the figures. Install the wall outlet in the correct position as shown in the figure. The centre of the inner pipe must be positioned above the centre of the outer pipe.
  • Page 19 Requirements 0.16 m 110/111/113 4,128 Concentric flue connection on appliance Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appliance (min. - max.) (min. - max.) is Ø130-Ø200 mm 0.5 - 1.0 m 0 - 0.6 m 1.0 - 2.0 m 0 - 2.6 m Gas Fire Panorama 70-55...
  • Page 20 Requirements 0.25 m 110/111/113 4,128 Concentric flue connection on appliance Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appliance (min. - max.) (min. - max.) is Ø130-Ø200 mm 0.5 - 1.0 m 0 - 1.6 m 1.0 - 3.0 m 0 - 4.6 m Gas Fire Panorama 70-55...
  • Page 21 Requirements 0.16 m 110/111/ 110/113 110/111/113 4,128 Concentric flue connection on appliance Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on (min. - max.) (min. - max.) (min. - max.) (min. - max.) the appliance is Ø130- Ø200 mm 0 - 0.5 m 0 - 0.5 m 0.5 - 1.0 m...
  • Page 22 Requirements 0.25 m 110/111/113 4,128 Concentric flue connection on appliance Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appliance (min. - max.) (min. - max.) is Ø130-Ø200 mm 0 - 0.5 m 0 - 0.6 m 0.5 - 1.0 m 0 - 3.6 m 1.0 - 3.0 m 0 - 8.6 m...
  • Page 23: Technical Specification

    Technical specification Technical specification Gas Fire Panorama 70-55 PF2 Frameless * = Adjustable Gas Fire Panorama 70-55...
  • Page 24: Gas Fire Panorama 70-55 Pf2 Frameless With Convection Casing

    Technical specification Gas Fire Panorama 70-55 PF2 Frameless with convection casing With optional convection case * = Adjustable Gas Fire Panorama 70-55...
  • Page 25: Gas Fire Panorama 70-55 Pf2 With 4 Cm Frame

    Technical specification Gas Fire Panorama 70-55 PF2 with 4 cm frame Gas Fire Panorama 70-55...
  • Page 26: Gas Fire Panorama 70-55 Pf2 With 4 Cm Frame And Convection Casing

    Technical specification Gas Fire Panorama 70-55 PF2 with 4 cm frame and convection casing Gas Fire Panorama 70-55...
  • Page 27: Gas Fire Panorama 70-55 Pf2 With 6 Cm Frame

    Technical specification Gas Fire Panorama 70-55 PF2 with 6 cm frame Gas Fire Panorama 70-55...
  • Page 28: Gas Fire Panorama 70-55 Pf2 With 6 Cm Frame And Convection Casing

    Technical specification Gas Fire Panorama 70-55 PF2 with 6 cm frame and convection casing With optional convection case Gas Fire Panorama 70-55...
  • Page 29: Gas Fire Panorama 70-55 Pf2 With 10 Cm Frame

    Technical specification Gas Fire Panorama 70-55 PF2 with 10 cm frame Gas Fire Panorama 70-55...
  • Page 30: Gas Fire Panorama 70-55 Pf2 With 10 Cm Frame And Convection Casing

    Technical specification Gas Fire Panorama 70-55 PF2 with 10 cm frame and convection casing Gas Fire Panorama 70-55...
  • Page 31: Gas Fire Panorama 70-55 Pf2 With 10 Cm Frame And Adjustable Legs

    Technical specification Gas Fire Panorama 70-55 PF2 with 10 cm frame and adjustable legs Gas Fire Panorama 70-55...
  • Page 32: Operating Unit

    Technical specification 5.10 Operating unit 5.11 Dimensions of the restriction plate Width of the delivered flue restriction plates in mm Concentric flue connection Ø100 - Ø150 Concentric flue connection Ø130 - Ø200 Roof-mounted outlet Horizontal wall outlet 30 mm 40 mm 40 mm 50 mm 50 mm...
  • Page 33: Available Components For The Concentric Flue System - Natural Draught

    Available components for the concentric flue system - natural draught Available components for the concentric flue system - natural draught Caution: Observe the installation instructions that are supplied with the components of the concentric flue system. The appliance with extraction of the flue gasses by natural draught, in combination with the concentric flue system [Ø100 mm - Ø150 mm] and/or [Ø130 mm - Ø200 mm] (rigid and/or flexible) for the brand types mentioned below, has been approved in accordance with the European CE-norm for gas appliances and may therefore be used only with...
  • Page 34: Bellfires - Muelink & Grol System Ø100 - Ø150

    Available components for the concentric flue system - natural draught Bellfires - Muelink & Grol system Ø100 - Ø150 Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Twin-wall balanced flue 302289 ● ● pipe. L= 500 mm. Twin-wall balanced flue 346236 pipe.
  • Page 35 Available components for the concentric flue system - natural draught Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Twin-wall balanced flue 302297 ● ● elbow 90°. (ribbed) Twin-wall balanced flue 346239 elbow 90°. (segment) ● ●...
  • Page 36 Available components for the concentric flue system - natural draught Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Vertical (roof) termina- 302295 tion kit, L= 1360 mm. ● ● ● ● ANTHRACITE Adjustable roof flash- 302212 ing.
  • Page 37 Available components for the concentric flue system - natural draught Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel 302215 Wall strap. ● ● ● Set of ceiling finishing 302214 ● ● ● plates / Fire stops. Ceiling plate for transi- tion Ø100 mm / Ø150 302189...
  • Page 38 Available components for the concentric flue system - natural draught Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Hose clamp Ø150 mm. 304042 (Minimum 2 per con- ● ● nection) Vertical (roof) termina- tion kit, L = 610 mm. 302307 Suitable for a flexible ●...
  • Page 39 Available components for the concentric flue system - natural draught used to extract the flue gasses. The temperature classification of the flexible pipe must be at least T450. Gas Fire Panorama 70-55...
  • Page 40: Bellfires - Muelink & Grol System Ø130 - Ø200

    Available components for the concentric flue system - natural draught Bellfires - Muelink & Grol system Ø130 - Ø200 Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Concentric reduc- tion of Ø130 / 302319 ● ●...
  • Page 41 Available components for the concentric flue system - natural draught Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Twin-wall balanced 302314 flue elbow 90°. (rib- ● ● bed) Twin-wall balanced 302315 flue elbow 45°. (rib- ●...
  • Page 42 Available components for the concentric flue system - natural draught Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Silicone seal Ø200 302248 ● ● 302251 Wall strap. ● ● Set of ceiling fin- 302250 ishing plates / Fire ●...
  • Page 43 Available components for the concentric flue system - natural draught Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Hose clamp Ø130 304045 mm. (Minimum 2 ● ● per connection). Hose clamp Ø200 304046 mm. (Minimum 2 ●...
  • Page 44: Poujoulat - Duogas System Ø100 - Ø150

    Available components for the concentric flue system - natural draught Poujoulat - DUOGAS system Ø100 - Ø150 Poujoulat Art./ Order Description 34100403 Twin-wall balanced flue pipe, L= 250 mm. 34100404 Twin-wall balanced flue pipe. L= 450 mm. 34100405 Twin-wall balanced flue pipe. L= 950 mm. Telescopic twin-wall balanced flue pipe, L= min.
  • Page 45 Available components for the concentric flue system - natural draught Poujoulat Art./ Order Description 34100654 Vertical (roof) termination kit, L= 140 mm . Roof flashing, suitable for a brick roof, with a roof pitch 45150171 of 15°- 30°. Roof flashing, suitable for a tiled roof, with a roof pitch 45150170 of 15°- 30°.
  • Page 46 Available components for the concentric flue system - natural draught Poujoulat Art./ Order Description 37100442 Ceiling/wall plate with spacers and ventilation grooves. Set of ceiling finishing plates / Fire stops, suitable for a 37100425 roof pitch of 0°- 10°. Set of ceiling finishing plates / Fire stops, suitable for a 37100426 roof pitch of 10°- 30°.
  • Page 47: Poujoulat - Duogas System Ø130 - Ø200

    Available components for the concentric flue system - natural draught Poujoulat - DUOGAS system Ø130 - Ø200 Poujoulat Art./ Order Description 34130403 Twin-wall balanced flue pipe, L= 250 mm. 34130404 Twin-wall balanced flue pipe. L= 450 mm. 34130405 Twin-wall balanced flue pipe. L= 950 mm. Telescopic twin-wall balanced flue pipe, L= min.
  • Page 48 Available components for the concentric flue system - natural draught Poujoulat Art./ Order Description Horizontal (wall) termination kit, L= min. 365 mm / max. 34130610 585 mm. 45200076 Stainless steel locking band Ø200 mm, quick-fastening. 45200072 Wall strap, Ø200 mm. 37130442 Ceiling/wall plate with spacers and ventilation grooves.
  • Page 49: Ontop - Metaloterm Us System Ø100 - Ø150

    Available components for the concentric flue system - natural draught Ontop - Metaloterm US system Ø100 - Ø150 Fig. Ontop Art. / Description Order No. Adapter for Bellfires appliances with Ø100-Ø150 mm USA 10 concentric connection. US 25 10 Twin-wall balanced flue pipe, L = 250 mm. US 50 10 Twin-wall balanced flue pipe.
  • Page 50 Available components for the concentric flue system - natural draught Fig. Ontop Art. / Description Order No. USB 15 10 Twin-wall balanced flue elbow 15°. USDVC2 10 Vertical (roof) termination kit, L= 375 mm. USSR 10 Storm collar Ø150 mm. Adjustable roof flashing.
  • Page 51 Available components for the concentric flue system - natural draught Fig. Ontop Art. / Description Order No. USAB 10 Cover band, screw-fastening. USMB 10 Wall strap, adjustable. USEB 10 Fitting bracket. Set of ceiling finishing plates / Fire stops / Centering USCP 10 plates.
  • Page 52 Available components for the concentric flue system - natural draught Fig. Ontop Art. / Description Order No. USKBS 10 Locking band, screw-fastening. USI 10 Concentric pipe with inspection panel, L= 250 mm. USEM 10 Concentric pipe with gauging orifice, L= 150 mm. USBI 10 90°...
  • Page 53: Ontop - Metaloterm Us System Ø130 - Ø200

    Available components for the concentric flue system - natural draught Ontop - Metaloterm US system Ø130 - Ø200 Fig. Ontop Art. / Description Order No. Adapter for Bellfires appliances with Ø100-Ø150 mm USA 13 concentric connection. US 25 13 Twin-wall balanced flue pipe, L = 250 mm. US 50 13 Twin-wall balanced flue pipe.
  • Page 54 Available components for the concentric flue system - natural draught Fig. Ontop Art. / Description Order No. USB 15 13 Twin-wall balanced flue elbow 15°. 116 USDVC2 13 Vertical (roof) termination kit, L= 375 mm. USSR 13 Storm collar Ø150 mm. Adjustable roof flashing.
  • Page 55 Available components for the concentric flue system - natural draught Fig. Ontop Art. / Description Order No. USAB 13 Cover band, screw-fastening. USMB 13 Wall strap, adjustable. USEB 13 Fitting bracket. Set of ceiling finishing plates / Fire stops / Centering USCP 13 plates.
  • Page 56 Available components for the concentric flue system - natural draught Fig. Ontop Art. / Description Order No. USKBS 13 Locking band, screw-fastening. USI 13 Concentric pipe with inspection panel, L= 250 mm. USEM 13 Concentric pipe with gauging orifice, L= 150 mm. USBI 13 90°...
  • Page 57 Available components for the concentric flue system - natural draught Fig. Ontop Art. / Description Order No. USAH 13 Spacer bracket. Concentric reduction of Ø130-Ø200 mm → Ø100-Ø150 USVG 13 10 Gas Fire Panorama 70-55...
  • Page 58: Jeremias/Stb - H-Twin System Ø100 - Ø150

    Available components for the concentric flue system - natural draught Jeremias/STB - H-Twin system Ø100 - Ø150 Jeremias Fig. Art. / Order Description ATWINL 13 Twin-wall balanced flue pipe. L= 1000 mm. 100-150 ATWINL 14 Twin-wall balanced flue pipe. L= 500 mm. 100-150 ATWINL 15 Twin-wall balanced flue pipe.
  • Page 59 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description ATWIN 17 Twin-wall balanced flue elbow 30°. 100-150 ATWIN 18 Twin-wall balanced flue elbow 45°. 100-150 ATWIN 60 Twin-wall balanced flue elbow 90°. 100-150 ATWIN 60F Twin-wall balanced flue elbow 90°...
  • Page 60 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description ATWIN 92 Roof termination - short with pipe, L = 300 mm, Verti- 100-150 cal. ATWIN Roof termination, with pipe, L = 495 mm, Vertical, with 92pe roof flashing for existing chimney or flat roof.
  • Page 61 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description A681 Horizontal (wall) termination kit, L= 495 mm (horizontal- 100-150 ly adjustable), including one set of wall spacer plates. H-TWIN 752 Concentric T-piece with gauging orifice. Inspection 100-150 panel with cover cap and condensation-opening.
  • Page 62: Jeremias/Stb - H-Twin System Ø130 - Ø200

    Available components for the concentric flue system - natural draught Jeremias/STB - H-Twin system Ø130 - Ø200 Jeremias Fig. Art. / Order Description ATWINL 13 Twin-wall balanced flue pipe. L= 1000 mm. 130-200 ATWINL 14 Twin-wall balanced flue pipe. L= 500 mm. 130-200 ATWINL 15 Twin-wall balanced flue pipe.
  • Page 63 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description ATWIN 17 Twin-wall balanced flue elbow 30°. 130-200 ATWIN 18 Twin-wall balanced flue elbow 45°. 130-200 ATWIN 60 Twin-wall balanced flue elbow 90°. 130-200 ATWIN 60F Twin-wall balanced flue elbow 90°...
  • Page 64 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description H-TWIN 752 Concentric T-piece with gauging orifice. Inspection 130-200 panel with cover cap and condensation-opening. ATWIN 465 Adapter: H-TWIN Ø130-200 → Flex Stainless steel ; 130-200 Ø130 mm Incl.
  • Page 65: Jeremias - Twin-Gas System Ø100 - Ø150

    Available components for the concentric flue system - natural draught 6.10 Jeremias - TWIN-GAS system Ø100 - Ø150 Jeremias Fig. Art. / Order Description Bellfires Appliance connection / Adapter Bellfires TWG1634 Ø100/150 mm → Jeremias TWIN-GAS Ø100/150 mm L 100-150 = 160 mm Including locking band (2x).
  • Page 66 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description TWG50 Telescopic twin-wall balanced flue pipe, L= min. 330 / 100-150 max. 420 mm Including locking band. TWG16 Twin-wall balanced flue elbow 15°. Including locking 100-150 band.
  • Page 67 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description TWG272 Roof termination (vertical) L= 615 mm. Including lock- 100-150 ing band. Roof flashing with a roof pitch of 5° - 15° with flex. alu- TW53 150 flashing and storm collar.
  • Page 68 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description TW45 150 Locking band, screw-fastening (spare part). ALBI26 150 Silicone sealing ring for outer pipe (spare part). ZUWA704 Wall strap. Distance to the wall: WA= 50 mm. Extension pieces for the wall strap ZUWA704 L= 130 WA891130 Extension pieces for the wall strap ZUWA704 L= 200...
  • Page 69 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description Set of ceiling finishing plates / Fire stops with ventila- DA99VHL tion openings for a pitched roof : 0° - 30°. Set of ceiling finishing plates / Fire stops with ventila- DA98VHL tion openings for a pitched roof : 31°...
  • Page 70 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description TWG07 Base plate / floor support. 100-150 Wall support with transverse support Type I: 350 mm DW391 - Distance to wall: WA= max. 50 mm. Wall support with transverse support Type II: 500 mm DW392 - Distance to wall: WA= 50 - 150 mm.
  • Page 71: Jeremias - Twin-Gas System Ø130 - Ø200

    Available components for the concentric flue system - natural draught 6.11 Jeremias - TWIN-GAS system Ø130 - Ø200 Jeremias Fig. Art. / Order Description Bellfires Appliance connection / Adapter Bellfires TWG1634 Ø130/200 mm → Jeremias TWIN-GAS Ø130/200 mm L 130-200 = 160 mm Including locking band (2x).
  • Page 72 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description TWG50 Telescopic twin-wall balanced flue pipe, L= min. 330 / 130-200 max. 420 mm Including locking band. TWG16 Twin-wall balanced flue elbow 15°. Including locking 130-200 band.
  • Page 73 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description TWG272 Roof termination (vertical) L= 615 mm. Including lock- 130-200 ing band. Roof flashing with a roof pitch of 5° - 15° with flex. alu- TW53 200 flashing and storm collar.
  • Page 74 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description TW45 200 Locking band, screw-fastening (spare part). 121 ALBI26 200 Silicone sealing ring for outer pipe (spare part). ZUWA704 Wall strap. Distance to the wall: WA= 50 mm. Extension pieces for the wall strap ZUWA704 L= 130 WA891130 Extension pieces for the wall strap ZUWA704 L= 200...
  • Page 75 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description Set of ceiling finishing plates / Fire stops with ventila- DA99VHL tion openings for a pitched roof : 0° - 30°. Set of ceiling finishing plates / Fire stops with ventila- DA98VHL tion openings for a pitched roof : 31°...
  • Page 76 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description TWG07 Base plate / floor support. 130-200 Wall support with transverse support Type I: 350 mm DW391 - Distance to wall: WA= max. 50 mm. Wall support with transverse support Type II: 500 mm DW392 - Distance to wall: WA= 50 - 150 mm.
  • Page 77: Modinox - Pla System Ø100 - Ø153

    Available components for the concentric flue system - natural draught 6.12 Modinox - PLA system Ø100 - Ø153 Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Bellfires appli- ance connec- tion: Adapter Bellfires Ø100/150 mm 2PLAMAFM100BEL ●...
  • Page 78 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Twin-wall bal- anced flue 2PLAELDR1001000 ● ● pipe, L= 1000 mm., INOX Twin-wall bal- anced flue 2PLAELDR1001000NO pipe, L= 1000 ●...
  • Page 79 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Twin-wall bal- anced flue el- 2PLACO15100 ● ● bow 15°, IN- Twin-wall bal- anced flue el- 2PLACO15100NO ●...
  • Page 80 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Roof flashing, standard model, lead: 0,6mm thick, 2DIVS5PS160 ● ● for a roof pitch of 5°- 30°, with INOX cone Roof flashing,...
  • Page 81 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Horizontal (wall) termina- tion kit, with 2PLATHOR100 rosettes, L= ● ● min. 580 mm / max. 780 mm. INOX Horizontal (wall) termina-...
  • Page 82 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Rosette, IN- 2PLAROSA100BT ● ● Rosette, IN- 2PLAROSA100BTNO ● ● OX - BLACK Rosette, IN- 2PLAROSA100BTBL ●...
  • Page 83 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Clearance 36 2PLAEPDS100 roof/floor pas- ● ● sage Adapter Modi- nox PLA → Flexible pipe, with chimney 2PLAADA71002020 ●...
  • Page 84 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Adapter Modi- nox PLA → Flexible pipe, with chimney 2PLAADA71003030 ● ● ● bottom finish- ing plate 300x300mm, INOX Adapter Modi-...
  • Page 85 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Adapter Flexi- ble pipe → Modinox PLA, with chimney 2PLAADA61002020 ● ● ● top finishing plate 200x200mm, INOX Adapter Flexi-...
  • Page 86 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Insulation kit 2PTGKIRA100 + la ISORA for ● ● pente pitched roof passage Insulation kit ISORA for pitched roof passage, roof 2PTGKIRAV100 + la...
  • Page 87: Modinox - Pla System Ø130 - Ø200

    Available components for the concentric flue system - natural draught 6.13 Modinox - PLA system Ø130 - Ø200 Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Bellfires appli- ance connec- tion: Adapter Bellfires Ø130/200 mm 2PLAMAFM130BEL ●...
  • Page 88 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel 2PLAMAFM130100 Adapter Modi- nox PLA Ø130/200 mm → Modinox ● ● Ø100/153 mm. L= 225 mm. INOX 2PLAMAFM130100NO Adapter Modi- nox PLA...
  • Page 89 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Telescopic twin-wall bal- anced flue 2PLAELRE130500 pipe, L= min. ● ● 300 / max. 500 mm., IN- 2PLAELRE130500NO Telescopic twin-wall bal-...
  • Page 90 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Vertical (roof) termination 2PLACHAR130 ● ● cap, L= 360 mm, INOX Vertical (roof) termination 2PLACHAR130NO cap, L= 360 ●...
  • Page 91 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Roof flashing, standard model, lead: 0,6mm thick, 2DIVS5PS200 ● ● for a roof pitch of 5°- 30°, with IN- OX cone Roof flashing,...
  • Page 92 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Horizontal (wall) termina- tion kit, with 2PLATHOR130 rosettes, L= ● ● min. 580 mm / max. 780 mm. INOX Horizontal (wall) termina-...
  • Page 93 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Rosette, IN- 2PLAROSA130BT ● ● Rosette, IN- 2PLAROSA130BTNO ● ● OX - BLACK Rosette, IN- 2PLAROSA130BTBL ●...
  • Page 94 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Clearance 136 2PLAEPDS130 roof/floor pas- ● ● sage 2PLAADA71302020 Adapter Modi- nox PLA → Flexible pipe, with chimney ●...
  • Page 95 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel 2PLAADA71303030 Adapter Modi- nox PLA → Flexible pipe, with chimney ● ● ● bottom finish- ing plate 300x300mm, INOX 2PLAADA71303030NO Adapter Modi-...
  • Page 96 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel 2PLAADA61302020 Adapter Flexi- ble pipe → Modinox PLA, with chimney ● ● ● top finishing plate 200x200mm, INOX 2PLAADA61302525...
  • Page 97 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Insulation kit 2PTGKIRA130 + la ISORA for ● ● pente pitched roof passage Insulation kit ISORA for pitched roof passage, roof 2PTGKIRAV130 + la...
  • Page 98 Available components for the concentric flue system - natural draught Gas Fire Panorama 70-55...
  • Page 99 Available components for the concentric flue system - natural draught Gas Fire Panorama 70-55...
  • Page 100 Your Barbas dealer 002 - 25.06.2021 - 351030...

Table of Contents