Page 1
INSTALLATION MANUAL ECO-55 ST (VB00022 model) Safety tested according to ULC S627,UL1482 and ASTM E1509 by an accredited laboratory INSTALLATION BY A PROFESSIONAL IS STRONGLY RECOMMENDED Stove Builder International inc. 250, rue de Copenhague, St-Augustin-de-Desmaures (Québec) Canada G3A 2H3 Customer service : 1-877-356-6663 Email : tech@sbi-international.com...
MONOXIDE IS TOXIC AND MAY CAUSE DEATH. published in any other media (owner’s manual, TO PREVENT THIS, ENSURE THAT YOUR catalogues, flyers, magazines or web sites). EXHAUST VENTING SYSTEM IS AIRTIGHT. Page 2 INSTALLATION MANUAL ECO-55 ST...
Page 3
This product expose chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.P65warnings.ca.gov/ INSTALLATION MANUAL ECO-55 ST Page 3...
DO NOT USE MAKESHIFT MATERIALS OR MAKE ANY COMPROMISES WHEN INSTALLING THIS STOVE. FRESH AIR INLET FLUE OUTLET 3" 76mm 3" 76mm 11 3/8" 6 1/8" 23 7/8" 290mm 155mm 607mm 24 7/8" 633mm Page 6 INSTALLATION MANUAL ECO-55 ST...
24" (610 mm) 24" (610 mm) *From the rear panel Note 1 : Refer to the exhaust venting system manufacturer’s **Measured from the platform on which the product is installed. instructions for clearances to combustible materials. INSTALLATION MANUAL ECO-55 ST Page 7...
Otherwise, see CSA B365. Note 1 : Refer to the exhaust venting system manufacturer’s instructions for clearances to combustible materials. 3.2 FLOOR PROTECTION Page 8 INSTALLATION MANUAL ECO-55 ST...
Moreover, a suitable venting system configuration will help getting the best efficiency out of your stove when installed in accordance with the required EVL. INSTALLATION MANUAL ECO-55 ST Page 9...
WARNING CAUTION TERMINATION COLLAR (SPARK ARRESTER) IS MANDATORY AND MUST BE CLEAR OF ANY • Horizontal runs shall not exceed 9 feet. DEBRIS AT ALL TIME. • Never exceed 30 feet of evl. Page 10 INSTALLATION MANUAL ECO-55 ST...
Cannot be located above a gas meter/regulator within 36" (91cm) horizontally of the vertical center line of the regulator; • Not within 6 feet (183 cm) of a gas service regulator vent outlet; • Other restrictions may apply. See NFPA 211 for further information. INSTALLATION MANUAL ECO-55 ST Page 11...
45 degree elbow facing towards the ground. The termination of the vent must include a spark arrester, fastened to the 45 degrees elbow. 8. Sealed outside wall thimbles with high temperature waterproof silicone sealant. Page 12 INSTALLATION MANUAL ECO-55 ST...
In the USA., the use of a stainless steel liner is mandatory. In Canada, it is not mandatory but is 5. Seal and install vertical roof vent. If required, seal strongly recommended. and install a storm collar. INSTALLATION MANUAL ECO-55 ST Page 13...
9. Seal and install vertical roof vent. If required, seal waterproof silicone sealant. 10. If desired, install a trim collar and use an addi- and install a storm collar. tional horizontal vent pipe length, if required, to connect the stove to the chimney. Page 14 INSTALLATION MANUAL ECO-55 ST...
(24 volts) is required. A fixed wall mount or hand held model can be used. NOTICE Thermostat manufacturer’s instructions always override the information published in the following section. INSTALLATION MANUAL ECO-55 ST Page 15...
It is recommended to install an outside air inlet in or near the room where the stove is installed. When doing so, it is preferable to choose a wall which is not exposed to dominant winds, depending on the conditions surrounding your house. Page 16 INSTALLATION MANUAL ECO-55 ST...
For a better seal, you may also use aluminum tape. Wrap the tape around the joint between the flexible pipe and the air inlets. Carefully push the insulation and plastic cover back over the pipe. Fix the plastic in place using aluminum tape. INSTALLATION MANUAL ECO-55 ST Page 17...
Test all around the door. The paper should not slip out easily. If it does, see the maintenance section in the operation manual. Remove all tools or accessories that have been in- serted in the stove for transportation purposes. Page 18 INSTALLATION MANUAL ECO-55 ST...
Page 26
HINGE PIN RETAINING RING 5/16" ID X 0.512" OD SE16059 ASH PLUG SE69759 BURN POT 44192 IGNITOR TUBE 30029 THREAD CUTTING SCREW 10-24 TYPE "F" X 3/8" HEX WASHER SE44132 IGNITER ASSEMBLY 120V 300W PL69777 FIRE BAFFLE 30417 BLACK HEX NUT #8-32 Page 26 INSTALLATION MANUAL ECO-55 ST...
Page 27
FUSE GLASS 4A 250VAC 5X20MM SLOW BLOW 60036 THERMOSTAT TERMINAL 60196 POWER CORD RECEPTACLE 30155 METAL SCREW #8 X 5/8'' PHILLIPS SELFTAPPING TEK ZINC 60331 POWER CORD 6' 49004 PRESSURE SWITCH HOSE 44029 PRESSURE SWITCH SE69849 AIR CONTROL DAMPER ASSEMBLY INSTALLATION MANUAL ECO-55 ST Page 27...