7 Installer Setup Service Setup; Pump Maximum Speed; Pump Down; Dry Concrete - Panasonic WH-ADC0912K6E5 Operating Instructions Manual

Air-to-water hydromodule + tank, indoor/outdoor unit
Table of Contents

Advertisement

Menus
For installer
Menu

7 Installer setup Service setup

7.1

Pump maximum speed

To set the maximum speed of
the pump.
7.2

Pump down

To set the pump down
operation.
7.3

Dry concrete

To dry the concrete (fl oor, walls,
etc.) during construction.
Do not use this menu for any
other purposes and in period
other than during construction
46
Default Setting
Setting Options / Display
Sterilization: Boiling temp.
Set boiling
65 °C
temperatures for
sterilize the tank.
Sterilization: Ope. time (max)
Set sterilizing time
0:10
(in hours and minutes)
Setting the fl ow rate, max. duty and operation
ON/OFF of the pump.
Flow rate: XX:X L/min
Max. Duty: 0x40 ~ 0xFE,
Pump: ON/OFF/Air Purge
Pump down operation
ON
Edit to set the temperature of dry concrete.
ON / Edit
Edit
Heating temperature
for drying the
Stages: 1
concrete.
Temperature: 25 °C
Select the desired
stages: 1 ~ 10,
range: 1 ~ 99
ON
Confi rm the setting temperatures of dry
concrete for each stage.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wh-adc0912k6e5anWh-uxz09ke5Wh-uxz12ke5

Table of Contents