Dhw Capacity; Buffer Tank Connection; Base Pan Heater; Alternative Outdoor Sensor - Panasonic WH-ADC0912K6E5 Operating Instructions Manual

Air-to-water hydromodule + tank, indoor/outdoor unit
Table of Contents

Advertisement

Menus
For installer
Menu
5.5

DHW capacity

To select tank heating capacity
to variable or standard. Variable
capacity heat up tank with
fast mode and keep the tank
temperature with effi cient mode.
While standard capacity heat up
tank with rated heating capacity.
5.6

Buffer tank connection

To connect tank to the system
and if selected YES, to set
T temperature.
5.7

Base pan heater

To select whether or not
optional base pan heater is
connected.
* Type A - The base pan heater
activates only during
deice operation.
* Type B - The base pan heater
activates when outdoor
ambient temperature is
5 °C or lower.
5.8

Alternative outdoor sensor

To select an alternative outdoor
sensor.
5.9

Bivalent connection

To select to enable or disable
bivalent connection.
Yes
To select either auto control
pattern or SG ready input
control pattern or smart control
pattern.
* This selection only display
to select when optional pcb
connection set to Yes.
32
Default Setting
Setting Options / Display
Variable
No
Yes
Set T for Buffer
5 °C
Tank
No
Yes
Set base pan heater
A
type*.
No
No
Auto
Buffer tank
10:34am,Mon
T for Buffer tank
Range: (0 ° C~10 ° C)
Steps: ±1 ° C
Select
Confirm
Auto
SG ready
Smart
° C
5