easywell EW-08HS Operation Manual

Ultrasonic atomizing humidifier

Advertisement

Quick Links

易仕韦尔
EASYWELL
EASYWELL
Ultrasonic Atomizing Humidifier
EW-08HS
Operation Manual
Content
1. Operational principle.............................................................................................................. 2
2. Configuration and technical parameters................................................................................. 2
3. Filter installation and cleaning................................................................................................3
4. Installation instruction............................................................................................................ 3
5. Atomization system................................................................................................................ 5
6. Regular failure and failure elimination................................................................................... 7
7. Maintenance............................................................................................................................8
8. Precautions..............................................................................................................................8
9. After-sales service...................................................................................................................9
Please read this carefully before using, and keep it for reference!
Easywell Electronic Co., Ltd.
第 1页

Advertisement

Table of Contents
loading

Summary of Contents for easywell EW-08HS

  • Page 1: Table Of Contents

    3. Filter installation and cleaning....................3 4. Installation instruction......................3 5. Atomization system........................ 5 6. Regular failure and failure elimination................... 7 7. Maintenance..........................8 8. Precautions..........................8 9. After-sales service........................9 Please read this carefully before using, and keep it for reference! Easywell Electronic Co., Ltd. 第 1页...
  • Page 2: Operational Principle

    1 to 5 mu water particles floating in the air, thereby to improve the air quality and improve the environment. 2. Configuration and technical parameters Model EW-08HS Mist capacity 8 L/hour Control method Intelligent microcomputer automatic control Voltage &...
  • Page 3: Filter Installation And Cleaning

    易仕韦尔 EASYWELL Working environment T: 1-40℃ H:≦85%RH Water pressure and water Water pressure: 0.1-0.4MPa temperature Water temperature:1-35℃ Suitable water type Clean water, Soft tap water Electrical pump,electromagnetic valve, water Devices equipped with shortage protector, water inlet filter 3. Filter installation and cleaning...
  • Page 4 易仕韦尔 EASYWELL in leveled to ensure the fog pressure smoothly so as to avoid the machine damaged by any blocking. In order to avoid the fog hole water beard down, the outlet hole of the fog should be located in the position of the PVC pipe cross section level up...
  • Page 5: Atomization System

    易仕韦尔 EASYWELL Fig 8 Fig 9 Tips: in the place where there is no need to install pipes, try not to fog along the front of the machine (the direction of the control panel), fog to the left, right or behind of the machine.
  • Page 6 易仕韦尔 EASYWELL affect the life of atomizer, the working life of atomized ceramic wafers is generally about 5,000 hours. When the atomizer runs for a long time, the spray amount is reduced or only the spray column is used, and some holes do not even produce fog, it is necessary to clean the water tank, or to replace a new atomizer or atomized ceramic wafers (energy exchange wafers).
  • Page 7: Regular Failure And Failure Elimination

    易仕韦尔 EASYWELL 6. Regular failure and failure elimination Fault symptom Reason Remove method Not working a) No Power a) Check the circuit, power b) Fuse blown restoration c) The power switch is not on b) Replace the fuse d) Humidity over the settled...
  • Page 8: Maintenance

    易仕韦尔 EASYWELL Fault symptom Reason Remove method c) The voltage became lower d) Adjust the water level d) The water level is too high or e) Clean the water tank and the less than the standard pipe e) There are oil in the water.
  • Page 9: After-Sales Service

    易仕韦尔 EASYWELL the fog out let should not be shorter than 1 meter. 4、 The outlet of the fog should be 1 meter from the equipment at least, and the total diameter of the mist vent is not less than the diameter of the mist vent of the equipment.
  • Page 10 易仕韦尔 EASYWELL Thank you very much for buying our company’s ultrasonic humidifiers. In order to better understand the installation and operation, to make full use of the equipment’s function. Please read this manual carefully before installing the equipment. We give 1 year warranty for the whole machine, in the warranty period, as a result of the failure problem of the product quality, our after-sales will give free maintenance.

Table of Contents