1 to 5 mu water particles floating in the air, thereby to improve the air quality and improve the environment. 2. Configuration and technical parameters Model EW-020HD Mist capacity 20 L/hour 第 2页...
易仕韦尔 EASYWELL Control method Intelligent microcomputer automatic control Voltage & Frequency AC220V±5%, 50~60Hz Power 1200W Machine size L/580*W/340*H/500(mm) Pipe diameter of fog outlet Ø110mm*2 Working environment T: 1-40℃ H:≦85%RH Water pressure and water Water pressure: 0.1-0.4MPa temperature Water temperature:1-35℃ Suitable water type...
易仕韦尔 EASYWELL Installation instruction Use the water pipe to connect the water supply inlet and the tap water source, then connect the electricity. Press the power on button, then the machine will work automatically, after a few seconds the machine will start to atomize automatically.
Page 5
易仕韦尔 EASYWELL L≤15m 12KG L≤20m L≤15m 18KG L≤20m Fig 8 and Fig 9 are the installation diagram Fig 8 Fig 9 Tips: in the place where there is no need to install pipes, try not to fog along the front of the machine (the direction of the control panel), fog to the left, right or behind of the machine.
Page 6
易仕韦尔 EASYWELL level exceeds the limit, the atomizer can not produce fog or spray column with a small amount of fog. The local water quality, environment, maintenance and other factors will directly affect the life of atomizer, the working life of atomized ceramic wafers is generally about 5,000 hours.
易仕韦尔 EASYWELL (Remark: To avoid the float displaced in transportation, please adjust the water level when the first time using.) 6. Regular failure and failure elimination Fault symptom Reason Remove method Not working a) No Power a) Check the circuit, power...
易仕韦尔 EASYWELL Fault symptom Reason Remove method became less or no tank atomization chip b) The atomization chip is too b) Replace the atomization chip aging c) Keep the standard voltage c) The voltage became lower d) Adjust the water level...
易仕韦尔 EASYWELL 2、 In principle, don’t add water from the outlet of fog , please connect the water pipe to input water. 3、 Direct humidification is not allowed, it is required that the pipe at the nozzle of the fog out let should not be shorter than 1 meter.
Page 10
易仕韦尔 EASYWELL and the storage water in the tank must be drained out entirely. As if the storage water stocked too long time, it will become ropy, this will affect the function of the equipment. 4、 The overflow and drain pipes must be connected to the floor drain to avoid accident caused by leakage.