Bosch Professional GRL 500 HV Manual page 26

Hide thumbs Also See for Professional GRL 500 HV:
Table of Contents

Advertisement

OBJ_BUCH-1960-004.book Page 47 Thursday, October 13, 2016 12:38 PM
Correction of Malfunctions
Malfunctions with Error Codes
Error Code
Indication
001
002
003
(GRL 500 HV)
004
005
006
007
008
009
020
033
Bosch Power Tools
Find Quality Products Online at:
The error code of a malfunction is shown on the display.
– Rectify the malfunction (see "Corrective Measure").
– Afterwards, simultaneously press the centre line mode button 19 and audio signal/volume button 24.
If the malfunction was successfully rectified, the error code indication goes out and automatic levelling will
start (see "Automatic Levelling during Operation", page 40).
If the malfunction persists, have the measuring tool checked by a Bosch customer service agent.
Problem
The X-axis of the measuring tool is outside of
the self-levelling range of approx. 8.5 %
(5°).
The Y-axis of the measuring tool is outside of
the self-levelling range of approx. 8.5 % (5°).
The Z-axis of the measuring tool in vertical
mode is outside of the self-levelling range of
approx. 8.5 % (5°).
Measuring tool is at a slant of more than
8.5 % after a position change.
The slope range of ±8.5 % has been ex-
ceeded in single-axis slope operation.
Duration of automatic levelling has been ex-
ceeded. Measuring tool cannot be levelled in.
The desired slope is not reached in single-
axis slope operation.
The rotation head of the laser is not rotating. – Simultaneously press the centre line mode button 19 and au-
During the search in centre line mode, the la-
ser beam reaches the end of the pivoting
range without finding the reception area of
the laser receiver.
External influences (e.g. falls or heavy im-
pacts) are interfering with centre line mode.
General error
Ambient light is too bright for the laser
receiver.
GlobalTestSupply
www.
Corrective Measure
– Reposition the measuring tool along the X-axis.
– Reposition the measuring tool along the Y-axis.
– Reposition the measuring tool in vertical mode along the
Z-axis.
– Reposition the measuring tool.
– Press the slope button 18 or 20 until a slope value of less than
8.5% is shown on the display (see "Slope Setting", page 40).
– Place the measuring tool on a stable surface or mount it in a sta-
ble manner on a tripod. The environment must be vibration-free.
– Place the measuring tool on a stable surface or mount it in a sta-
ble manner on a tripod. The environment must be vibration-free.
dio signal/volume button 24.
– Switch the measuring tool off (see "Switching Off", page 38).
– Switch the measuring tool back on.
– Check whether the visual contact between measuring tool and
laser receiver has been interrupted and reposition the meas-
uring tool if necessary.
If the error continues to occur, reduce the distance between
measuring tool and laser receiver.
– Reposition the measuring tool.
Place the measuring tool on a stable surface or mount it in a sta-
ble manner on a tripod. The environment must be vibration-free.
– Restart the search to find the centre line (see "Centre Line
Mode", page 40).
Ensure that the pivoting range of the laser beam is not interrupt-
ed by persons or other visual obstacles during the search.
If the error continues to occur, reduce the distance between
measuring tool and laser receiver.
– Simultaneously press the centre line mode button 19 and au-
dio signal/volume button 24.
– Switch the measuring tool off (see "Switching Off", page 38).
– Switch the measuring tool back on.
– Shade the reception area.
1 609 92A 274 | (13.10.16)
.com
English | 47
sales@GlobalTestSupply.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Professional grl 500 hProfessional lr 50

Table of Contents