Haier 1U25YAMFRA Installation Manual page 9

Table of Contents

Advertisement

Installation Instructions
Post-installation Inspection Items and Test Run
I
e t
m
s
o t
B
e
C
e h
k c
d e
Whether the installation is firm or not
Whether the inspection on air leakage is completed The refrigerating capacity (heating capacity) may be
Whether the unit is fully insulated
Whether the drainage is smooth or not
Whether the power voltage is identical to that
marked on the nameplate
Whether the circuit and pipeline are installed
correctly
Whether the unit is safely earthed
Whether the type of wire is in line with relevant
regulations
Whether barriers are identified at the air inlet/outlet
of the indoor/outdoor unit
Whether the length of refrigerant pipes and the
refrigerant amount charged are recorded
1.
Preparations
(1)
Power on is not allowed before all the installation operations are completed and before the leak
detection is proven qualified.
(2)
The control circuit shall be connected correctly and all the wires shall be firmly connected.
(3)
The two-way stop valve and three-way stop valve shall be opened.
(4)
All the scattered articles (especially the metal filing and thread residue) shall be removed from the unit
body.
2.
Methods
(1)
Switch on the power supply and press the "ON/OFF" on the remote controller, after which the air
conditioner will start operating.
(2)
Press "Mode" to select refrigeration, heating and sweeping wind, and observe whether the air
conditioner is under normal operation.
DRED Installation Instruction
Please consult your reseller and/or installer to determine if you have a DRED appliance.
1
Open cover piece and locate board.
1U25YAMFRA
There are different kinds of electrical box coup ling. Select DRED module installation position
2
according to the actual outdoor unit.
Post-installation Inspection Items
C
o
s n
q e
uence of Improper Installation
The unit may fall, vibrate or make a noise
insufficient
Condensation or drip may occur
Condensation or drip may occur
Failure may occur or the parts may be burned
Failure may occur or the parts may be burned
Electric leakage may occur
Failure may occur or the parts may be burned
The refrigerating capacity (heating capacity) may be
insufficient
The refrigerant amount charged cannot be confirmed
Test Run
1U35MAMFRA
7
Dred Installation Instruction
1U50KAMFRA
1U71KAMFRA